JPR 8550.1 - Nasa
JPR 8550.1 - Nasa
JPR 8550.1 - Nasa
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
JSC Environmental Compliance<br />
Procedural Requirements<br />
<strong>JPR</strong> No.<br />
<strong>8550.1</strong>A XXXX.X<br />
Effective Date:<br />
Johnson Space Center • Environmental Compliance Program<br />
Expiration Date:<br />
Expiration Date:<br />
Page Number<br />
3/25/2011<br />
3/25/2016<br />
[Leave Blank]<br />
Page 31 of 123<br />
(1) Clearly and legibly label each container with the following: ―WARNING: CONTAINS LEAD<br />
POISON.‖<br />
(2) Mark all bagged waste with the generator’s name (responsible person), organization,<br />
removal location and removal date.<br />
3.6.8 Labeling Waste Containing Polychlorinated Biphenyls (PCBs)<br />
a. Generators of waste containing PCBs shall comply with the requirements below:<br />
(1) Non-leaking small capacitors with total volume of less than 100 cubic inches and<br />
fluorescent lamp ballasts if they are not labeled ―NON-PCB‖:<br />
(a) Clearly and legibly label each container with a description of the contents of the container<br />
(e.g., ―waste ballasts‖).<br />
(b) Do not use ―Hazardous Waste‖ labels or PCB labels.<br />
(c) Mark the date on the container that the waste was first placed inside.<br />
(d) Do not tape paper labels to waste containers.<br />
(2) For leaking small capacitors (total volume of less than 100 cubic inches), fluorescent light<br />
ballasts, and transformers, follow spill/release procedures in Chapter 12, Handling and<br />
Reporting Spills and Releases.<br />
(3) For PCB containing ballasts, transformers or other equipment which are not labeled ―NON-<br />
PCB‖ by the manufacturer, mark the date the ballast or other equipment was removed from<br />
service and call for waste pickup.<br />
3.6.9 Labeling Unknown Waste<br />
a. Generators who discover unknown wastes within their work area shall:<br />
(1) Mark the unknown material (RED HAZARD TAG) as ―Unknown – Pending Evaluation by<br />
Environmental‖ and notify X33333 for immediate attention.<br />
(2) Do not move or open the container holding the unknown from the original place of<br />
discovery. Potential dangers exist to untrained personnel handling unknown chemicals due to<br />
the inability to determine physical hazards (flammability, oxidizers) or health hazards (routes of<br />
entry, personal protective equipment).<br />
3.6.10 Labeling Gas Cylinders<br />
Generators shall maintain the original manufacturer’s label on the cylinder.<br />
3.6.11 Labeling Used Oil and Halogenated Waste Oil<br />
a. Generators shall comply with the following requirements for non-halogenated used oil:<br />
Verify correct version before use at<br />
http://server-mpo.arc.nasa.gov/Services/CDMSDocs/Centers/JSC/Home.tml.<br />
JSC Form JF2420B (MS Word August 28, 2006) (Revised May 30, 2007)