JSC Environmental Compliance<br />

Procedural Requirements<br />

<strong>JPR</strong> No.<br />

<strong>8550.1</strong>A XXXX.X<br />

Effective Date:<br />

Johnson Space Center • Environmental Compliance Program<br />

Expiration Date:<br />

Expiration Date:<br />

Page Number<br />

3/25/2011<br />

3/25/2016<br />

[Leave Blank]<br />

Page 33 of 123<br />

Note: The EO will initiate the posting of specific identification signs and marking of the SAA with<br />

paint or tape.<br />

3.8 Accumulation Limits and Requirements<br />

3.8.1 Satellite Accumulation Areas (SAAs)<br />

a. Generators shall only accumulate up to 55 gallons of ISW (if not acutely hazardous) before<br />

calling for waste pickup.<br />

b. Accumulation times shall comply with the following requirements:<br />

(1) For laboratories, do not accumulate waste in a container for more than three months.<br />

(2) For all other areas, do not accumulate waste for more than six months.<br />

Note: Acutely hazardous wastes have different storage limits. However, acutely hazardous<br />

wastes are rarely generated at JSC and will be flagged and the generator notified of<br />

requirements when the form JF1104 is submitted.<br />

3.8.2 Prohibitions<br />

a. Generators shall never move waste from one SAA to another SAA.<br />

b. Generators shall never bring wastes from an offsite facility (e.g. contractor owned or leased<br />

facility) to JSC or transfer wastes from one site (JSC, EF, SCTF, EPFOL) to another.<br />

3.8.3 Secondary Containment Requirements<br />

a. Generators shall obtain a secondary containment structure if the total capacity of liquid<br />

waste storage at a location is greater than 55 gallons and is outdoors (i.e., when there are<br />

multiple, adjacent SAAs and the aggregate capacity of all SAAs).<br />

b. The secondary containment structure shall be impervious and be able to hold the entire<br />

capacity of the largest container plus either contain or divert a 10-inch rainfall amount.<br />

c. Generators shall only contact the Facilities Contractor for draining. Containment draining<br />

and removal of drain caps by any other individuals is prohibited.<br />

d. Generators shall call Facilities Work Control, at X32038, if a waste containment structure is<br />

leaking, full or overflowing, or if waste or material has been spilled into the containment.<br />

e. Contact the EO for additional requirements related to secondary containments.<br />

3.8.4 Shipment for Disposal<br />

a. The generator shall record the date that waste is first placed in the device in order to ensure<br />

that the date is tracked and the requirement is met.<br />

Verify correct version before use at<br />

http://server-mpo.arc.nasa.gov/Services/CDMSDocs/Centers/JSC/Home.tml.<br />

JSC Form JF2420B (MS Word August 28, 2006) (Revised May 30, 2007)