Chapter 8<br />

Device management<br />

125<br />

Figure 52.Input Groups Form<br />

Fields and controls<br />

Table 55. Input Groups form fields<br />

Field<br />

Description<br />

Description<br />

Type a description of the Input Group, usually including a micro wiring address.<br />

Note:<br />

In single input groups and in a hierarchy of input groups, all inputs in any given group or<br />

hierarchy must be associated with the same micro.<br />

Delay Time<br />

Type the number of seconds an input must be true (On State or Change State) before the input group is<br />

true. This delay helps avoid false input detections.<br />

Notes:<br />

• The Off To On Delay Time and On To Off Delay Time set on the Inputs form overrides the Delay<br />

Time set on the Input Groups form.<br />

• Set Delay Time to zero for any input group assigned to an exit push button.