178<br />

<strong>Picture</strong> <strong>Perfect</strong> <strong>4.6</strong><br />

<strong>User</strong> <strong>Manual</strong><br />

Table 80. Readers form fields (continued)<br />

Field<br />

Description<br />

Authorization Required<br />

Select Yes to designate a reader that displays a photo in a popup window<br />

beside the Activity Monitor and requires an operator to unlock a door.<br />

Select No to designate a reader that displays a photo in a popup window<br />

beside the Activity Monitor and unlocks a door without operator intervention.<br />

Note:<br />

The Yes and No buttons are not available unless Swipe and Show<br />

is Enabled. <br />

Access cannot be granted through readers defined as<br />

Authorization Required while communications to the micro are<br />

down.<br />

Logical Reader<br />

Function<br />

Select the desired Logical Reader Function for this reader:<br />

Normal<br />

Used to grant access into an area.<br />

Anti-Passback In<br />

Anti-Passback Out<br />

Time and Attendance<br />

In/Out<br />

Time and Attendance<br />

In<br />

Time and Attendance<br />

Out<br />

Nested APB<br />

Used to log a badge holder “in” when entering.<br />

Used to log a badge holder “out” when exiting.<br />

Used to log a badge holder “in” and “out” using the same reader (such as<br />

the Model 100 Wiegand reader) by swiping the badge the normal way for<br />

“in” and reversing the badge or turning the badge backwards for “out”.<br />

Used to log a badge holder “in” at the start of a work shift.<br />

Used to log a badge holder “out” at the end of a work shift<br />

Used to configure APB on nested areas.<br />

APB<br />

If the Logical Reader Function is set to APB In, APB Out, or Nested APB, select the desired APB<br />

Type for this reader:<br />

<strong>Global</strong> APB<br />

Timed APB<br />

Reset Timed APB<br />

Immediately<br />

Timed APB Duration<br />

Used as the default, this allows the host to share APB status/nested APB<br />

area status with participating controllers.<br />

Used to designate the reader as a Timed APB reader in which a badge<br />

holder’s APB status/nested APB area returns to Neutral after a defined<br />

period of time. A Timed APB reader is useful in a site where a badge holder<br />

may enter a site by going through an APB reader but is not required to exit<br />

the site by going through an APB reader. If this option is selected, a Timed<br />

APB Duration must also be defined. A Timed APB status/nested APB area<br />

is local to the micro.<br />

Used to reset the Timed APB status/nested APB area back to Neutral<br />

immediately following a badge swipe.<br />

Enter a value to represent how long a badge holder’s Timed APB status/<br />

nested APB area is set when the badge is used on the reader. The Timed<br />

APB Duration cannot exceed one day. A duration of 0 allows the micro to<br />

reset the status to Neutral immediately, producing the same effect as Reset<br />

Timed APB Immediately.