Chapter 9<br />

Area management<br />

179<br />

Table 80. Readers form fields (continued)<br />

Field<br />

Description<br />

<strong>Global</strong> Nested APB<br />

Status Method<br />

<strong>Global</strong> Nested APB<br />

Micro Offline Operation<br />

Mode<br />

This control is enabled only if Nested APB under Logical Reader Function<br />

has been chosen.<br />

Host Broadcasts to Controllers - The host actively sends nested APB area<br />

information to participating controllers.<br />

Controller Requests from Host - The controller requests nested APB area<br />

information from the host as needed.<br />

This control is enabled only if Controller Requests from Host has been<br />

chosen.<br />

Fail Safe - While the controller is offline, the controller does not consider<br />

nested APB area information when granting access.<br />

Fail Secure - While the controller is offline, the controller denies access to<br />

nested APB readers.<br />

Note:<br />

There is a period of time when the controller loses communication<br />

with the host, where it is not offline yet and during this time, when a<br />

badge is swiped on a Controller Requests From Host type (Fail<br />

Safe) reader, a learn timeout is generated. Once the controller is<br />

offline, the fail safe/fail secure rules are followed to provide or deny<br />

access.<br />

Scheduling<br />

Shunting<br />

Toggle<br />

Limited Usage<br />

Elevator Reader<br />

Enabled means established schedule changes control this reader.<br />

Disabled means established schedule changes do not affect this reader.<br />

Enabled means this reader allows the use of keypad override of shunt time.<br />

Disabled means the reader does not allow shunting.<br />

When enabled, the Alarm Shunting feature allows a valid badge holder to keep a door open (for the<br />

time specified, in minutes, in the Keypad Shunt Time field of the Doors form) without getting a Door<br />

Held Open alarm. The badge holder enters the shunt code (defined on the Micros form) using the<br />

reader keypad, presents the badge, and then enters the PIN number.<br />

A reader used in special applications only, in which a badge swipe toggles the reader’s valid input<br />

group (non-boolean) On (yes) or Off (no), such as to arm/disarm a burglar alarm system. Toggle<br />

readers are not intended for door control, but can be used that way with some limitations. To do this,<br />

the door must be configured without a sensor, and the doorstrike output must be configured to reset<br />

with an input rather than on duration. With this configuration, the reader can toggle the door between<br />

locked and unlocked, but since there is no sensor, there can be no detection of the door being forced<br />

open or held open too long.<br />

For an example of toggle-reader use, see Creating input groups on page 123 of Chapter 8 Device<br />

management.<br />

Note:<br />

If Toggle is set to Yes and Authorization Required is set to Yes, photos are displayed for<br />

invalid transactions, but not valid transactions. See Monitoring Swipe and Show activity on<br />

page 263.<br />

Selecting Enabled defines the reader as a limited usage reader, which only grants access to a badge<br />

holder for the number of times specified in the Usage Count field of the Badges form.<br />

There is no limit to the number of readers that can be defined as limited usage readers. See<br />

Chapter 11 Badge management for related information. The count must be manually reset.<br />

Selecting Yes defines the reader as an elevator reader. A maximum of 16 readers on a micro can be<br />

configured as elevator readers.<br />

Note: Swipe and Show cannot be enabled when the reader is defined as elevator reader.<br />

See Elevator control on page 360 for related information.