30.01.2015 Views

Picture Perfect 4.6 User Manual - UTCFS Global Security Products

Picture Perfect 4.6 User Manual - UTCFS Global Security Products

Picture Perfect 4.6 User Manual - UTCFS Global Security Products

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

260<br />

<strong>Picture</strong> <strong>Perfect</strong> <strong>4.6</strong><br />

<strong>User</strong> <strong>Manual</strong><br />

responses selected from the Responses list box exceed this limit, a warning displays and the<br />

response is truncated to the maximum length. The response may then be edited in the Enter<br />

New Response: box to make the truncated response more presentable.<br />

6. Log the response.<br />

• To log the response without clearing the alarm, click OK. You can continue to select this<br />

alarm again to enter new responses. The previous responses appear in the Responses<br />

To Date box.<br />

• To log the response and clear the alarm, click Remove on the Alarm Response window.<br />

See Related procedures on page 255.<br />

7. Optional: Click the close button (X button) to close the window without altering the state of the<br />

alarm.<br />

Monitoring badge activity<br />

The Badge Monitor displays the following types of badge activities:<br />

Table 107.Badge activities - Valid<br />

Valid transactions<br />

APB In<br />

APB Out<br />

Degraded Open<br />

Open<br />

Open Duress<br />

Open Shunt<br />

Passive APB In<br />

Passive APB Out<br />

Swipe And Show<br />

T&A In<br />

T&A Out<br />

Valid Door Locked<br />

Valid Floor<br />

Valid No Passage<br />

Valid Toggle<br />

Valid Nested APB<br />

A valid read occurred in an Antipassback In reader.<br />

A valid read occurred in an Antipassback Out reader<br />

A read occurred when an 8RP board was offline from the Micro/4 CPU.<br />

A valid read occurred in a Normal reader or a Keypad reader and the door was opened.<br />

A valid read occurred in a Keypad reader but was followed by a duress code. The door was<br />

opened.<br />

The door was opened as part of an alarm shunting process.<br />

A badge holder was granted access in two successive APB IN readers.<br />

A badge holder was granted access in two successive APB OUT readers.<br />

A valid read occurred on a reader configured for Swipe and Show. This is followed by<br />

another valid transaction, indicating how the transaction ended.<br />

A valid read occurred in a Time & Attendance In reader.<br />

A valid read occurred in a Time & Attendance Out reader.<br />

In a double-badge reader, the first badge read was valid but does not open the door until the<br />

second is validated.<br />

A valid floor number was selected with elevator reader/DI/DO configuration.<br />

A valid read occurred but the door was not opened.<br />

A valid read occurred in a Toggle reader which reversed the current state of the Input<br />

Group.<br />

A valid read occurred at a nested APB reader.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!