outputs (and inputs in the case of Reader/DI/DO configurations) to the corresponding floors. Perform<br />

this setup for each of the access-controlled elevators in your facility.<br />

Figure 181.Elevator Form<br />

Fields and controls<br />

Table 132.Elevators form fields<br />

Field<br />

Description<br />

Facility<br />

Configuration<br />

Type<br />

Micro<br />

Reader<br />

Fire DO after<br />

Floor<br />

Selection<br />

Description<br />

Type any alphanumeric combination to describe the elevator (up to 60 alphanumeric characters).<br />

Example: Lobby, East Wing 1, West Wing 3<br />

Click Facility to display the facilities list box. This field reflects the facility to which this record is assigned.<br />

For more information, see Creating facilities on page 52.<br />

Select one of the following types:<br />

• Micro/DO - See To set up Example 2 in a Micro/DO configuration: on page 369.<br />

• Reader/DO - See To set up Example 2 Reader/DO configuration: on page 369.<br />

• Reader/DI/DO - See To set up Example 2 in a Reader/DI/DO configuration: on page 370.<br />

When using the Micro/DO configuration type, click to select a micro from the list box. If multiple readers<br />

are configured on an elevator micro, the first reader controls the elevator.<br />

When using the Reader/DO or the Reader/DI/DO configuration type, click to select a reader from the list<br />

box.<br />

When using the Reader/DI/DO configuration type, select the Fire DO after Floor Selection to enable<br />

Elevator Access Method 2 in which, after a valid badge read, a floor has to be selected and if it is an<br />

accessible floor, the DO is activated. Otherwise, the default Method 1 in which, after a valid badge read,<br />

the DOs for all accessible floors are activated, is employed.<br />

CAUTION: Whenever the Fire DO after Floor Selection option is toggled and the change is saved on the<br />

Elevator form, the micros reset. The duration of the reset depends on the number of badges defined in<br />