Chapter 13<br />

Alarm/activity monitors<br />

263<br />

Table 109.Badge Monitor fields (continued)<br />

Field<br />

Employee ID<br />

Initials<br />

Last Name<br />

First Name<br />

Reader<br />

Category<br />

Area<br />

Department<br />

BID<br />

Facility<br />

Description<br />

The badge holder’s employee number.<br />

The badge holder’s initials.<br />

The badge holder’s last name.<br />

The badge holder’s first name.<br />

The description of the reader that read this badge.<br />

The description of the category that resulted in the valid transaction.<br />

The description of the area where the reader is located.<br />

The description of the department that the badge holder belongs to.<br />

The unique identification number associated with this badge.<br />

The facility of the input as defined in the Facility field of the Badges form.<br />

Monitoring Swipe and Show activity<br />

When configured for Swipe and Show, the Activity Monitor displays a photo when a valid badge read<br />

is received from a reader. The photo is imported from the photo database. For double-badge<br />

transactions, the photo is displayed when the first swipe is detected, and the door is allowed to be<br />

unlocked when the second swipe is detected.<br />

To enable the Swipe And Show function, the reader must be designated as Authorization Required<br />

or Authorization Not Required on the Reader form. Enable Swipe And Show Monitor must be<br />

selected on the Image Options tab of the Badge Monitor Preferences window. This option is<br />

available only when the Image package is installed in the system.<br />

Figure 112.Swipe and Show Monitor<br />

If Authorization Required is active, a dialog allows the operator to unlock the door or advises the<br />

operator why the door cannot be unlocked. If the door is allowed to be unlocked, the dialog includes<br />

an OK button and a Cancel button. The OK button unlocks the door and dismisses the dialog. The<br />

Cancel button dismisses the dialog, but does not unlock the door. If the door is not allowed to be<br />

unlocked, the dialog only shows a Close button, which dismisses the dialog.<br />

If the operator clicks the OK button to unlock the door, the door strike output command event is<br />

recorded in operator history. Any invalid transaction denies the operator the option of unlocking the<br />

door.