nanodac RECORDER/CONTROLLER: USER GUIDEFigure 4.5.2 shows a typical totaliser configuration page.Virtual Channel.1.MainDescriptorTypeOperationPVStatusResolutionUnitsUnits ScalerLow Cut OffHigh Cut OffInput1PeriodPresetPreset ValueRolloverRollover ValueDisableVirtualChan1TotaliserOn180.3625 unitsGood4units10100000327.11 secNo0No1000000Input 1Totaliser1 to 10 6Input 1RolloverCounter 110 6 to 10 12Input 1RolloverCounter 210 12 to 10 18RolloverUsing cascaded counters to expandthe totalisation range.Figure 4.5.2 Typical totaliser configuration menuDescriptorTypeOperationPVStatusResolutionUnitsUnits ScalerAllows the user to enter a descriptor (20 characters max.) for the totaliser.Select: Math, Counter or Totaliser.Allows the user to enable (‘On’) or disable (‘Off’) the totaliser.Read only. This is the dynamic output value of the totaliser.Read only. Shows the status of the totaliser.The Resolution parameter allows the number of decimal places (up to 6) to be set forthe totalised value as displayed on the instrument panel. It does not affect the resolutionof the totalisation process. Up to 6 decimal places may be set for the totalised value.Allows a units string of up to five characters to be entered for the totalised value.Allows a units scaler to be selected. Typically this will be used to scale between unittypes rather than to influence time period.One example of this would be when an input is measured in Litres/Minute, and Periodhas been set to 1Minute. If UnitsScaler is set to 1 then the total volume will be measuredin Litres. If the volume is required in Cubic Metres then conversion of the total will beneeded. There are 1000 Litres in a Cubic Metre so the UnitsScaler should be set to1000. This produces an additional division of 1000 and results in a total output in CubicMetres.Another example would be a requirement for the output in Gallons rather than litres,still with an input being measured in Litres/Minute. There are 4.54609 litres in an imperialgallon so the UnitsScaler would be set to 4.54609. (For a US Gallon the figure wouldbe 3.78541.)Low Cut Off Used to restrict the input operating range of the totaliser. Minimum value = -100 000High Cut Off Used to restrict the input operating range of the totaliser. Maximum value = 100 000Page 92HA030554Issue 7 Nov 12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!