11.07.2015 Views

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

nanodac RECORDER/CONTROLLER: USER GUIDEParameter path Description Type Hex Dec ResolutionSegment.26.Ch1Time Channel 1 time time_t 3f74 16244 Set by Network.Modbus.TimeFormatSegment.26.Ch1TSP Channel 1 target set-point float32 3f72 16242 Same as Programmer.SetUp.Ch1PVInputSegment.26.Ch1<strong>User</strong>Val Channel 1 user value float32 3f88 16264 Same as Programmer.SetUp.ResetCh1<strong>User</strong>ValSegment.26.Ch1Wait Channel 1 Wait uint8 3f7e 16254 Not applicableSegment.26.Ch1WaitVal Channel 1 wait value float32 3f80 16256 Same as Programmer.SetUp.PVWait1Segment.26.Ch2Holdback Channel 2 holdback type uint8 3f7a 16250 Not applicableSegment.26.Ch2HoldbackVal Channel 2 holdback value float32 3f7c 16252 Same as Programmer.SetUp.Ch2PVInputSegment.26.Ch2PVEvent Channel 2 PV event uint8 3f85 16261 Not applicableSegment.26.Ch2PVEventUse Channel 2 PV event use bool 3f93 16275 Not applicableSegment.26.Ch2PVEventVal Channel 2 PV event value float32 3f87 16263 Same as Programmer.SetUp.Ch2PVInputSegment.26.Ch2Rate Channel 2 rate float32 3f77 16247 Set by Programmer.SetUp.RateResolutionSegment.26.Ch2Time Channel 2 time time_t 3f75 16245 Set by Network.Modbus.TimeFormatSegment.26.Ch2TSP Channel 2 target set-point float32 3f73 16243 Same as Programmer.SetUp.Ch2PVInputSegment.26.Ch2<strong>User</strong>Val Channel 2 user value float32 3f89 16265 Same as Programmer.SetUp.ResetCh2<strong>User</strong>ValSegment.26.Ch2Wait Channel 2 Wait uint8 3f7f 16255 Not applicableSegment.26.Ch2WaitVal Channel 2 wait value float32 3f81 16257 Same as Programmer.SetUp.PVWait2Segment.26.Cycles Cycles int16 3f83 16259 Not applicableSegment.26.Duration Duration time_t 3f71 16241 Set by Network.Modbus.TimeFormatSegment.26.EndType End type uint8 3f78 16248 Not applicableSegment.26.Event1 Event 1 bool 3f8a 16266 Not applicableSegment.26.Event2 Event 2 For parameterbool 3f8b 16267 Not applicableSegment.26.Event3 Event 3values and settingsbool 3f8c 16268 Not applicableSegment.26.Event4 Event 4 bool 3f8d 16269 Not applicableSegment.26.Event5 Event 5 (enumerations),bool 3f8e 16270 Not applicableSegment.26.Event6 Event 6 see Segment 1bool 3f8f 16271 Not applicableSegment.26.Event7 Event 7 bool 3f90 16272 Not applicableSegment.26.Event8 Event 8 bool 3f91 16273 Not applicableSegment.26.GoBackTo Go back to uint8 3f82 16258 Not applicableSegment.26.SegmentName Segment name string_t 6cdd 27869 Not applicableSegment.26.Type Type uint8 3f70 16240 Not applicableSegment.26.WaitFor Wait for uint8 3f7d 16253 Not applicableSteriliser.AutoCounter Automatically increments the cycle number bool 2e0f 11791 Not applicableSteriliser.CycleNumber Current cycle number int32 2e04 11780 Not applicableSteriliser.CycleStatus The current cycle status. uint8 2e08 11784 Not applicable0 = Waiting start 1 = Waiting 2 = Equilibrisation3 = Sterilising 4 = Passed 5 = Failed6 = Aborted 7 = Test cycleSteriliser.CycleTime The total cycle time time_t 2e25 11813 Set by Network.Modbus.TimeFormatSteriliser.EquilibrationTime The equilibration time period for the current cycle. time_t 2e0c 11788 Set by Network.Modbus.TimeFormatSteriliser.FailureDwell1 Failure alarm dwell time for input 1 time_t 2e22 11810 Set by Network.Modbus.TimeFormatSteriliser.FailureDwell2 Failure alarm dwell time for input 2 time_t 2e2b 11819 Set by Network.Modbus.TimeFormatSteriliser.FailureDwell3 Failure alarm dwell time for input 3 time_t 2e2c 11820 Set by Network.Modbus.TimeFormatSteriliser.FailureDwell4 Failure alarm dwell time for input 4 time_t 2e2d 11821 Set by Network.Modbus.TimeFormatSteriliser.FileByTag Name historical files by cycle number and tag bool 2e21 11809 Not applicable0 = File by Tag Off; 1 = File by Tag OnSteriliser.FileTag Used as part of the historical filename string_t 68f7 26871 Not applicableSteriliser.Fvalue F0 (A0) time_t 2e26 11814 Set by Network.Modbus.TimeFormatSteriliser.Input1PV Input 1 float32 2e00 11776 0dpSteriliser.Input2PV Input 2 float32 2e01 11777 0dpSteriliser.Input3PV Input 3 float32 2e02 11778 0dpSteriliser.Input4PV Input 4 float32 2e03 11779 0dpSteriliser.InputType1 Input type 1 uint8 2e1d 11805 Not applicable0 = Off 1 = thermocouple 2 = Rising pressure3 = Falling pressure 4 = Rise air detect 5 = Fall air detectSteriliser.InputType2 Input type 2 (as Input type 1, above) uint8 2e1e 11806 Not applicableSteriliser.InputType3 Input type 3 (as Input type 1, above) uint8 2e1f 11807 Not applicableSteriliser.InputType4 Input type 4 (as Input type 1, above) uint8 2e20 11808 Not applicableSteriliser.IP1BandHigh Sterilisation temperature input 1 band high. float32 2e0a 11786 Same as Steriliser.Input1PVSteriliser.IP1BandLow Sterilisation temperature input 1 band low. float32 2e0b 11787 Same as Steriliser.Input1PVSteriliser.IP1TargetSP Input 1 target setpoint float32 2e07 11783 Same as Steriliser.Input1PVSteriliser.IP2BandHigh Sterilisation temperature input 2 band high. float32 2e10 11792 Same as Steriliser.Input2PVSteriliser.IP2BandLow Sterilisation temperature input 2 band low. float32 2e11 11793 Same as Steriliser.Input2PVSteriliser.IP2TargetSP Input 2 target setpoint float32 2e16 11798 Same as Steriliser.Input2PVSteriliser.IP3BandHigh Sterilisation temperature input 3 band high. float32 2e12 11794 Same as Steriliser.Input3PVSteriliser.IP3BandLow Sterilisation temperature input 3 band low. float32 2e13 11795 Same as Steriliser.Input3PVSteriliser.IP3TargetSP Input 3 target setpoint float32 2e17 11799 Same as Steriliser.Input3PVSteriliser.IP4BandHigh Sterilisation temperature input 4 band high. float32 2e14 11796 Same as Steriliser.Input4PVSteriliser.IP4BandLow Sterilisation temperature input 4 band low. float32 2e15 11797 Same as Steriliser.Input3PVSteriliser.IP4TargetSP Input 4 target setpoint float32 2e18 11800 Same as Steriliser.Input4PVSteriliser.LowLimit Low temperature limit for the F0 calculation. float32 2e2a 11818 0dpSteriliser.MeasuredTemp Measured Temperature used in the F0 calculation. float32 2e27 11815 0dpSteriliser.PassedOutput 1 = cycle passed; 0 = cycle failed. uint8 2e1c 11804 Not applicableSteriliser.Remaining The holding time remaining for the current cycle. time_t 2e0e 11790 Set by Network.Modbus.TimeFormatPage 233HA030554Issue 7 Nov 12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!