11.07.2015 Views

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

nanodac RECORDER/CONTROLLER: USER GUIDEParameter path Description Type Hex Dec ResolutionRealTimeEvent.2.OnDay Sets the day the event is to switch on (as for Event 1) uint8 30f3 12531 Not applicableRealTimeEvent.2.OnMonth Sets the month that the event is to switch on uint8 30f1 12529 Not applicableRealTimeEvent.2.OnTime Sets the time that the event is to switch On time_t 30f4 12532 Set by Network.Modbus.TimeFormatRealTimeEvent.2.Output The output from the real time event (0 = Off; 1 = On) bool 30fb 12539 Not applicableRealTimeEvent.2.Type Selects the type of Real Time Event uint8 30f0 12528 Not applicable0 = Off 1 = Time and Day 2 = Time and DateSegment.1.Ch1Holdback Channel 1 holdback type uint8 3ac9 15049 Not applicable0 = Off 1 = Low 2= High 3 = BandSegment.1.Ch1HoldbackVal Channel 1 holdback value float32 3acb 15051 Same as Programmer.SetUp.Ch1PVInputSegment.1.Ch1PVEvent Channel 1 PV event uint8 3ad4 15060 Not applicable0 = Off 1 = Absolute High 2 = Absolute Low3 = Deviation High 4 = Deviation Low 5 = Deviation BandSegment.1.Ch1PVEventUse Channel 1 PV event use (0 = Trigger; 1 = Alarm) bool 3ae2 15074 Not applicableSegment.1.Ch1PVEventVal Channel 1 PV event value float32 3ad6 15062 Same as Programmer.SetUp.Ch1PVInputSegment.1.Ch1Rate Channel 1 rate float32 3ac6 15046 Set by Programmer.SetUp.RateResolutionSegment.1.Ch1Time Channel 1 time time_t 3ac4 15044 Set by Network.Modbus.TimeFormatSegment.1.Ch1TSP Channel 1 target set-point float32 3ac2 15042 Same as Programmer.SetUp.Ch1PVInputSegment.1.Ch1<strong>User</strong>Val Channel 1 user value float32 3ad8 15064 Same as Programmer.SetUp.ResetCh1<strong>User</strong>ValSegment.1.Ch1Wait Channel 1 Wait (Analogue 1 criterion) uint8 3ace 15054 Not applicable1= Abs high 2 = Abs low 3 = Dev high 4 = Dev LowSegment.1.Ch1WaitVal Channel 1 wait value float32 3ad0 15056 Same as Programmer.SetUp.PVWait1Segment.1.Ch2Holdback Channel 2 holdback type (as for Ch1Holdback, above) uint8 3aca 15050 Not applicableSegment.1.Ch2HoldbackVal Channel 2 holdback value float32 3acc 15052 Same as Programmer.SetUp.Ch2PVInputSegment.1.Ch2PVEvent Channel 2 PV event (as for Ch1PVEvent, above) uint8 3ad5 15061 Not applicableSegment.1.Ch2PVEventUse Channel 2 PV event use (as for Ch1PVEventUse, above) bool 3ae3 15075 Not applicableSegment.1.Ch2PVEventVal Channel 2 PV event value float32 3ad7 15063 Same as Programmer.SetUp.Ch2PVInputSegment.1.Ch2Rate Channel 2 rate float32 3ac7 15047 Set by Programmer.SetUp.RateResolutionSegment.1.Ch2Time Channel 2 time time_t 3ac5 15045 Set by Network.Modbus.TimeFormatSegment.1.Ch2TSP Channel 2 target set-point float32 3ac3 15043 Same as Programmer.SetUp.Ch2PVInputSegment.1.Ch2<strong>User</strong>Val Channel 2 user value float32 3ad9 15065 Same as Programmer.SetUp.ResetCh2<strong>User</strong>ValSegment.1.Ch2Wait Channel 2 Wait (analogue 2 criterion; as for Ch1Wait, above) uint8 3acf 15055 Not applicableSegment.1.Ch2WaitVal Channel 2 wait value float32 3ad1 15057 Same as Programmer.SetUp.PVWait2Segment.1.Cycles Cycles (0 = Continuous) int16 3ad3 15059 Not applicableSegment.1.Duration Duration time_t 3ac1 15041 Set by Network.Modbus.TimeFormatSegment.1.EndType End type (0 = Dwell; 1 = Reset) uint8 3ac8 15048 Not applicableSegment.1.Event1 Event 1 (0 = Off; 1 = On) bool 3ada 15066 Not applicableSegment.1.Event2 Event 2 (0 = Off; 1 = On) bool 3adb 15067 Not applicableSegment.1.Event3 Event 3 (0 = Off; 1 = On) bool 3adc 15068 Not applicableSegment.1.Event4 Event 4 (0 = Off; 1 = On) bool 3add 15069 Not applicableSegment.1.Event5 Event 5 (0 = Off; 1 = On) bool 3ade 15070 Not applicableSegment.1.Event6 Event 6 (0 = Off; 1 = On) bool 3adf 15071 Not applicableSegment.1.Event7 Event 7 (0 = Off; 1 = On) bool 3ae0 15072 Not applicableSegment.1.Event8 Event 8 (0 = Off; 1 = On) bool 3ae1 15073 Not applicableSegment.1.GoBackTo Go back to uint8 3ad2 15058 Not applicableSegment.1.SegmentName Segment name string_t 6ad0 27344 Not applicableSegment.1.Type Type uint8 3ac0 15040 Not applicable0 = End 1 = Ramp 2 = Dwell3 = Step 4 = Wait 5 = GoBackSegment.1.WaitFor Wait for uint8 3acd 15053 Not applicable0 = Digital High 1 = Wait analogue 12 = Wait analogue 2 3 = Wait analogue 1 and analogue 2Segment.2.Ch1Holdback Channel 1 holdback type uint8 3af9 15097 Not applicableSegment.2.Ch1HoldbackVal Channel 1 holdback value float32 3afb 15099 Same as Programmer.SetUp.Ch1PVInputSegment.2.Ch1PVEvent Channel 1 PV event uint8 3b04 15108 Not applicableSegment.2.Ch1PVEventUse Channel 1 PV event use bool 3b12 15122 Not applicableSegment.2.Ch1PVEventVal Channel 1 PV event value float32 3b06 15110 Same as Programmer.SetUp.Ch1PVInputSegment.2.Ch1Rate Channel 1 rate float32 3af6 15094 Set by Programmer.SetUp.RateResolutionSegment.2.Ch1Time Channel 1 time time_t 3af4 15092 Set by Network.Modbus.TimeFormatSegment.2.Ch1TSP Channel 1 target set-point float32 3af2 15090 Same as Programmer.SetUp.Ch1PVInputSegment.2.Ch1<strong>User</strong>Val Channel 1 user value float32 3b08 15112 Same as Programmer.SetUp.ResetCh1<strong>User</strong>ValFor parameterSegment.2.Ch1Wait Channel 1 Wait uint8 3afe 15102 Not applicableSegment.2.Ch1WaitVal Channel 1 wait value values and settings float32 3b00 15104 Same as Programmer.SetUp.PVWait1Segment.2.Ch2Holdback Channel 2 holdback type(enumerations),uint8 3afa 15098 Not applicableSegment.2.Ch2HoldbackVal Channel 2 holdback value float32 3afc 15100 Same as Programmer.SetUp.Ch2PVInputSegment.2.Ch2PVEvent Channel 2 PV event see Segment 1uint8 3b05 15109 Not applicableSegment.2.Ch2PVEventUse Channel 2 PV event use bool 3b13 15123 Not applicableSegment.2.Ch2PVEventVal Channel 2 PV event value float32 3b07 15111 Same as Programmer.SetUp.Ch2PVInputSegment.2.Ch2Rate Channel 2 rate float32 3af7 15095 Set by Programmer.SetUp.RateResolutionSegment.2.Ch2Time Channel 2 time time_t 3af5 15093 Set by Network.Modbus.TimeFormatSegment.2.Ch2TSP Channel 2 target set-point float32 3af3 15091 Same as Programmer.SetUp.Ch2PVInputSegment.2.Ch2<strong>User</strong>Val Channel 2 user value float32 3b09 15113 Same as Programmer.SetUp.ResetCh2<strong>User</strong>ValSegment.2.Ch2Wait Channel 2 Wait uint8 3aff 15103 Not applicableSegment.2.Ch2WaitVal Channel 2 wait value float32 3b01 15105 Same as Programmer.SetUp.PVWait2Segment.2.Cycles Cycles int16 3b03 15107 Not applicableSegment.2.Duration Duration time_t 3af1 15089 Set by Network.Modbus.TimeFormatSegment.2.EndType End type uint8 3af8 15096 Not applicableSegment.2.Event1 Event 1 bool 3b0a 15114 Not applicablePage 221HA030554Issue 7 Nov 12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!