11.07.2015 Views

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

nanodac RECORDER/CONTROLLER: USER GUIDEParameter path Description Type Hex Dec ResolutionAdvancedLoop.Diag.CalcOP Calc OP float32 031f 799 1dpAdvancedLoop.Diag.HiSatLim HiSatLim float32 0320 800 1dpAdvancedLoop.Diag.LoSatLim LoSatLim float32 0321 801 1dpAdvancedLoop.Diag.MasterDerivativeOutContrib Master derivative output contribution float32 0312 786 0dpAdvancedLoop.Diag.MasterError Master error float32 030d 781 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.Diag.MasterFB Master feedback float32 031e 798 1dpAdvancedLoop.Diag.MasterIntegralOutContrib Master integral output contribution float32 0311 785 4dpAdvancedLoop.Diag.MasterLoopBreakAlarm Master loop break (0 = No; 1 = Yes) bool 0323 803 Not applicableAdvancedLoop.Diag.MasterPropOutContrib Master loop proportional output contribution float32 0310 784 0dpAdvancedLoop.Diag.MasterSensorBreak Master sensor break (0 = Off, 1 = On) bool 0313 787 Not applicableAdvancedLoop.Diag.OPPid OPPID float32 0322 802 1dpAdvancedLoop.Diag.SchedCBH Scheduled cutback high float32 3195 12693 0dpAdvancedLoop.Diag.SchedCBL Scheduled cutback low float32 3196 12694 0dpAdvancedLoop.Diag.SchedLPBrk Scheduled loop break time float32 3198 12696 0dpAdvancedLoop.Diag.SchedMR Scheduled manual reset float32 3197 12695 1dpAdvancedLoop.Diag.SchedOutputHigh Scheduled output high limit float32 319a 12698 1dpAdvancedLoop.Diag.SchedOutputLow Scheduled output low limit float32 319b 12699 1dpAdvancedLoop.Diag.SchedPB Scheduled proportional band float32 3192 12690 1dpAdvancedLoop.Diag.SchedR2G Scheduled relative cool gain float32 3199 12697 1dpAdvancedLoop.Diag.SchedTd Scheduled derivative time float32 3194 12692 1dpAdvancedLoop.Diag.SchedTi Scheduled integral time float32 3193 12691 1dpAdvancedLoop.Diag.SlaveDerivativeOutContrib Slave derivative output contribution float32 031d 797 0dpAdvancedLoop.Diag.SlaveError Slave error float32 031a 794 Same as AdvancedLoop.Main.SlavePVAdvancedLoop.Diag.SlaveIntegralOutContrib Slave integral output contribution float32 031c 796 4dpAdvancedLoop.Diag.SlaveLoopBreakAlarm Slave loop break (0 = No; 1 = Yes) bool 030f 783 Not applicableAdvancedLoop.Diag.SlavePropOutContrib Slave loop proportional output contribution float32 031b 795 0dpAdvancedLoop.Diag.SlaveSensorBreak Slave sensor break (0 = Off; 1 = On) bool 0325 805 Not applicableAdvancedLoop.Diag.TargetOutput Target output float32 030e 782 Same as AdvancedLoop.Output.OutputHighLimitAdvancedLoop.Diag.WorkingOutputHigh Slave output high limit float32 0315 789 0dpAdvancedLoop.Diag.WorkingOutputLow Slave output low limit float32 0314 788 0dpAdvancedLoop.Main.ActiveOut Working output float32 0303 771 Same as AdvancedLoop.Output.OutputHighLimitAdvancedLoop.Main.CascadeMode Cascade mode (0 = Cascade; 1 = Slave; 2 = Manual) uint8 0316 790 Not applicableAdvancedLoop.Main.Inhibit Control inhibit (0 = No; 1 = Yes) bool 0304 772 Not applicableAdvancedLoop.Main.MasterIntHold Master integral hold (0 = No; 1 = Yes) uint8 0305 773 Not applicableAdvancedLoop.Main.MasterPV Master loop process variable float32 0317 791 1dpAdvancedLoop.Main.MasterWSP Master loop working setpoint float32 0318 792 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.Main.SlaveIntHold Slave integral hold (0 = No; 1 = Yes) uint8 0306 774 Not applicableAdvancedLoop.Main.SlavePV Slave loop process variable float32 0300 768 1dpAdvancedLoop.Main.SlaveWSP Slave loop working setpoint float32 0302 770 Same as AdvancedLoop.Main.SlavePVAdvancedLoop.Main.TargetSetpoint Target setpoint float32 0301 769 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.MasterPID.ControlAction Control action (0 = Reverse acting; 1 = Direct acting) uint8 3103 12547 Not applicableAdvancedLoop.MasterPID.CutbackHigh Cutback high (0 = Auto) float32 31af 12719 1dpAdvancedLoop.MasterPID.CutbackLow Cutback low (0 = Auto) float32 31b0 12720 1dpAdvancedLoop.MasterPID.DerivativeTime Derivative time (0 = Off) float32 31ae 12718 1dpAdvancedLoop.MasterPID.DerivativeType Derivative type ( 0 = PV; 1 = Eror) uint8 3105 12549 Not applicableAdvancedLoop.MasterPID.ErrorLimit Error limit float32 31cc 12748 1dpAdvancedLoop.MasterPID.IntegralTime Integral time (0 = Off) float32 31ad 12717 1dpAdvancedLoop.MasterPID.LoopBreakTime Loop break time (0 = Off) float32 31b2 12722 0dpAdvancedLoop.MasterPID.ManualReset Manual reset float32 31b1 12721 1dpAdvancedLoop.MasterPID.PBUnits Proportional band units (0 = Engineering; 1 = Percentage) uint8 3104 12548 Not applicableAdvancedLoop.MasterPID.ProportionalBand Proportional band float32 31ac 12716 1dpAdvancedLoop.MasterSP.AltSP Alternative setpoint float32 3160 12640 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.MasterSP.AltSPSelect Alternative setpoint enable (0 = No; 1 = Yes) uint8 3161 12641 Not applicableAdvancedLoop.MasterSP.ManualTrack Manual track enable (0 = Off; 1 = On) uint8 3167 12647 Not applicableAdvancedLoop.MasterSP.RangeHigh Range high float32 3159 12633 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.MasterSP.RangeLow Range low float32 315a 12634 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.MasterSP.Rate Setpoint rate limit value (0 = Off) float32 3162 12642 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.MasterSP.RateDisable Setpoint rate limit disable (0 = No; 1 = Yes) bool 3163 12643 Not applicableAdvancedLoop.MasterSP.RateDone Setpoint rate limit complete (0 = No; 1 = Yes) bool 030a 778 Not applicableAdvancedLoop.MasterSP.ServoToPV Servo to PV enable (0 = No; 1 = Yes) bool 316c 12652 Not applicableAdvancedLoop.MasterSP.SP1 Setpoint 1 float32 315c 12636 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.MasterSP.SP2 Setpoint 2 float32 315d 12637 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.MasterSP.SPHighLimit Setpoint high limit float32 315e 12638 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.MasterSP.SPIntBal SP integral balance (0 = Off; 1 = On) bool 316b 12651 Not applicableAdvancedLoop.MasterSP.SPLowLimit Setpoint low limit float32 315f 12639 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.MasterSP.SPSelect Active setpoint select (0 - Setpoint 1; 1 = Setpoint 2) uint8 315b 12635 Not applicableAdvancedLoop.MasterSP.SPTrack Setpoint tracking enable (0 = Off; 1 = On) uint8 3168 12648 Not applicableAdvancedLoop.MasterSP.SPTrim Setpoint trim float32 3164 12644 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.MasterSP.SPTrimHighLimit Setpoint trim high limit float32 3165 12645 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.MasterSP.SPTrimLowLimit Setpoint trim low limit float32 3166 12646 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.MasterSP.TrackPV Track PV float32 3169 12649 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.MasterSP.TrackSP Track SP float32 316a 12650 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.Output.Ch1OnOffHysteresis Channel 1 on/off hysteresis float32 3172 12658 Same as AdvancedLoop.Main.MasterPVAdvancedLoop.Output.Ch1Output Channel 1 output value float32 030b 779 Same as AdvancedLoop.Output.OutputHighLimitAdvancedLoop.Output.Ch1PotBreak Channel 1 potentiometer break (0 = Off; 1 = On) uint8 3179 12665 Not applicableAdvancedLoop.Output.Ch1PotPosition Channel 1 valve position float32 3178 12664 0dpAdvancedLoop.Output.Ch1TravelTime Channel 1 travel time float32 3174 12660 1dpAdvancedLoop.Output.Ch2Deadband Channel 2 deadband (0 = Off) float32 316f 12655 Same as AdvancedLoop.Output.Out-HA030554Issue 7 Nov 12Page 176

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!