11.07.2015 Views

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

nanodac RECORDER/CONTROLLER: USER GUIDE4.13 DC OUTPUTThis option provides a voltage (terminals 3A3B only) or mA output. Terminal location is shown in figure 2.2.CAUTIONThere are no mechanical interlocks to prevent a chassis with the dc output option being fitted into a‘sleeve’ or ‘case’ which has previously been wired for the standard relay output. Before fitting thechassis into the case, it should be ensured that the terminal wiring is not attached to live voltage supplies,as such voltages may cause permanent damage to the instrument.4.13.1 Configuration displayAs shown in the figure below, highlight the required DC output, then operate the scroll button to reveal theconfiguration page.DC Output.3A3B (DC Op)Select configuration menuTypeVNetworkGroupChannelVirtual ChannelLoopDigital I/ODC Output3A3B (DC.Op)2A2B (DC.Op)1A1B (DC.Op)PVStatusOP Adjust StateResolutionOutput LowOutput HighScale LowScale High0.00GoodAdjusted20.0010.000.00100.00Appears only ifthe DC Outputhas been adjusted(Section4.1.10)Fallback PV0.00Measured Value0.00PARAMETERSTypePVStatusOP Adjust StateResolutionOutput LowOutput HighScale LowScale HighFallback PVMeasured ValueFigure 4.13.1 DC Output option configuration page (typical)Select V(olts) (3A3B only) or mA as the output type.Input value to the function. Normally ‘wired’ to a suitable parameter.The status of the input parameter.Adjusted. Appears only if the Output Adjust facility (Section 4.1.10) has been used.The number of decimal places to be used for this configuration item.The minimum output value in Volts or mA as appropriateThe maximum output value to be output in Volts or mA as appropriate.See ‘SCALING INFORMATION’ below.See ‘SCALING INFORMATION’ below.The output value when the status of the input parameter is not ‘good’.The Voltage or mA value appearing at the output terminalsNote: The output voltage or current can be calibrated by using the output adjust proceduredescribed in Section 4.1.10.SCALING INFORMATIONWhen PV = Scale Low, Output = output low value. When PV = Scale high, Output = output high value. ThePV is mapped via the scale range onto the output range according to the equation:( Output High - Output Low ) Output LowOutput = PV - Scale Low⎜ ⎛⎟⎞+⎝ Scale High - Scale Low ⎠Page 148HA030554Issue 7 Nov 12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!