nanodac RECORDER/CONTROLLER: USER GUIDEParameter path Description Type Hex Dec ResolutionVirtualChannel.16.Main.PresetValue Specifies the preset value float32 238d 9101 Set by VirtualChannel.16.Main.ResolutionVirtualChannel.16.Main.PV The virtual channel output value float32 015c 348 Set by VirtualChannel.16.Main.ResolutionVirtualChannel.16.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 238b 9099 Not applicableVirtualChannel.16.Main.Resolution Specifies the resolution/number of decimal places uint8 2382 9090 Not applicableVirtualChannel.16.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 2391 9105 Not applicableVirtualChannel.16.Main.RolloverValue Rollover value float32 2392 9106 Set by VirtualChannel.16.Main.ResolutionVirtualChannel.16.Main.Status As VirtualChannel1.Main.Status uint8 015d 349 Not applicableVirtualChannel.16.Main.TimeRemaining Time remaining before the calculation is made time_t 2389 9097 Set by Network.Modbus.TimeFormatVirtualChannel.16.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes bool 238e 9102 Not applicableVirtualChannel.16.Main.Type As VirtualChannel1.Main.Type uint8 2380 9088 Not applicableVirtualChannel.16.Main.Units Units descriptor string_t 4cab 19627 Not applicableVirtualChannel.16.Main.UnitsScaler Units scaler for totalisers float32 2383 9091 1dpVirtualChannel.16.Trend.Colour As VirtualChannel1.Trend.Colour uint8 23a0 9120 Not applicableVirtualChannel.16.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 23a2 9122 Same as VirtualChannel.16.Main.PVVirtualChannel.16.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 23a1 9121 Same as VirtualChannel.16.Main.PVVirtualChannel.17.Main.Descriptor Virtual Channel descriptor string_t 4cb1 19633 Not applicableVirtualChannel.17.Main.Disable 1 = Virtual channel disabled bool 23e3 9187 Not applicableVirtualChannel.17.Main.HighCutOff The highest input value that will be totalised/counted float32 23c5 9157 Set by VirtualChannel.17.Main.ResolutionVirtualChannel.17.Main.Input1 Input 1 value float32 23c7 9159 Set by VirtualChannel.17.Main.ResolutionVirtualChannel.17.Main.Input2 Input 2 value float32 23c8 9160 Set by VirtualChannel.17.Main.ResolutionVirtualChannel.17.Main.LowCutOff The lowest input value that will be totalised/counted float32 23c4 9156 Set by VirtualChannel.17.Main.ResolutionVirtualChannel.17.Main.ModbusInput Modbus input value float32 23c6 9158 Set by VirtualChannel.17.Main.ResolutionVirtualChannel.17.Main.Operation Specifies the operation of the virtual channel uint8 23c1 9153 Not applicableVirtualChannel.17.Main.Period The time period over which the calculation is made int32 23ca 9162 Not applicableVirtualChannel.17.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 23cc 9164 Not applicableVirtualChannel.17.Main.PresetValue Specifies the preset value float32 23cd 9165 Set by VirtualChannel.17.Main.ResolutionVirtualChannel.17.Main.PV The virtual channel output value float32 015e 350 Set by VirtualChannel.17.Main.ResolutionVirtualChannel.17.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 23cb 9163 Not applicableVirtualChannel.17.Main.Resolution Specifies the resolution/number of decimal places uint8 23c2 9154 Not applicableVirtualChannel.17.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 23d1 9169 Not applicableVirtualChannel.17.Main.RolloverValue Rollover value float32 23d2 9170 Set by VirtualChannel.17.Main.ResolutionVirtualChannel.17.Main.Status As VirtualChannel1.Main.Status uint8 015f 351 Not applicableVirtualChannel.17.Main.TimeRemaining Time remaining before the calculation is made time_t 23c9 9161 Set by Network.Modbus.TimeFormatVirtualChannel.17.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes bool 23ce 9166 Not applicableVirtualChannel.17.Main.Type As VirtualChannel1.Main.Type uint8 23c0 9152 Not applicableVirtualChannel.17.Main.Units Units descriptor string_t 4cc6 19654 Not applicableVirtualChannel.17.Main.UnitsScaler Units scaler for totalisers float32 23c3 9155 1dpVirtualChannel.17.Trend.Colour As VirtualChannel1.Trend.Colour uint8 23e0 9184 Not applicableVirtualChannel.17.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 23e2 9186 Same as VirtualChannel.17.Main.PVVirtualChannel.17.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 23e1 9185 Same as VirtualChannel.17.Main.PVVirtualChannel.18.Main.Descriptor Virtual Channel descriptor string_t 4ccc 19660 Not applicableVirtualChannel.18.Main.Disable 1 = Virtual channel disabled bool 2523 9507 Not applicableVirtualChannel.18.Main.HighCutOff The highest input value that will be totalised/counted float32 2405 9221 Set by VirtualChannel.18.Main.ResolutionVirtualChannel.18.Main.Input1 Input 1 value float32 2407 9223 Set by VirtualChannel.18.Main.ResolutionVirtualChannel.18.Main.Input2 Input 2 value float32 2408 9224 Set by VirtualChannel.18.Main.ResolutionVirtualChannel.18.Main.LowCutOff The lowest input value that will be totalised/counted float32 2404 9220 Set by VirtualChannel.18.Main.ResolutionVirtualChannel.18.Main.ModbusInput Modbus input value float32 2406 9222 Set by VirtualChannel.18.Main.ResolutionVirtualChannel.18.Main.Operation Specifies the operation of the virtual channel uint8 2401 9217 Not applicableVirtualChannel.18.Main.Period The time period over which the calculation is made int32 240a 9226 Not applicableVirtualChannel.18.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 240c 9228 Not applicableVirtualChannel.18.Main.PresetValue Specifies the preset value float32 240d 9229 Set by VirtualChannel.18.Main.ResolutionVirtualChannel.18.Main.PV The virtual channel output value float32 0160 352 Set by VirtualChannel.18.Main.ResolutionVirtualChannel.18.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 240b 9227 Not applicableVirtualChannel.18.Main.Resolution Specifies the resolution/number of decimal places uint8 2402 9218 Not applicableVirtualChannel.18.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 2411 9233 Not applicableVirtualChannel.18.Main.RolloverValue Rollover value float32 2412 9234 Set by VirtualChannel.18.Main.ResolutionVirtualChannel.18.Main.Status As VirtualChannel1.Main.Status uint8 0161 353 Not applicableVirtualChannel.18.Main.TimeRemaining Time remaining before the calculation is made time_t 2409 9225 Set by Network.Modbus.TimeFormatVirtualChannel.18.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes) bool 240e 9230 Not applicableVirtualChannel.18.Main.Type As VirtualChannel1.Main.Type uint8 2400 9216 Not applicableVirtualChannel.18.Main.Units Units descriptor string_t 4ce1 19681 Not applicableVirtualChannel.18.Main.UnitsScaler Units scaler for totalisers float32 2403 9219 1dpVirtualChannel.18.Trend.Colour As VirtualChannel1.Trend.Colour uint8 2520 9504 Not applicableVirtualChannel.18.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 2522 9506 Same as VirtualChannel.18.Main.PVVirtualChannel.18.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 2521 9505 Same as VirtualChannel.18.Main.PVVirtualChannel.19.Main.Descriptor Virtual Channel descriptor string_t 4ce7 19687 Not applicableVirtualChannel.19.Main.Disable 1 = Virtual channel disabled bool 2563 9571 Not applicableVirtualChannel.19.Main.HighCutOff The highest input value that will be totalised/counted float32 2445 9285 Set by VirtualChannel.19.Main.ResolutionVirtualChannel.19.Main.Input1 Input 1 value float32 2447 9287 Set by VirtualChannel.19.Main.ResolutionVirtualChannel.19.Main.Input2 Input 2 value float32 2448 9288 Set by VirtualChannel.19.Main.ResolutionVirtualChannel.19.Main.LowCutOff The lowest input value that will be totalised/counted float32 2444 9284 Set by VirtualChannel.19.Main.ResolutionVirtualChannel.19.Main.ModbusInput Modbus input value float32 2446 9286 Set by VirtualChannel.19.Main.ResolutionVirtualChannel.19.Main.Operation Specifies the operation of the virtual channel uint8 2441 9281 Not applicableVirtualChannel.19.Main.Period The time period over which the calculation is made int32 244a 9290 Not applicableVirtualChannel.19.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 244c 9292 Not applicableVirtualChannel.19.Main.PresetValue Specifies the preset value float32 244d 9293 Set by VirtualChannel.19.Main.ResolutionVirtualChannel.19.Main.PV The virtual channel output value float32 0162 354 Set by VirtualChannel.19.Main.ResolutionVirtualChannel.19.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 244b 9291 Not applicableHA030554Issue 7 Nov 12Page 251

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!