nanodac RECORDER/CONTROLLER: USER GUIDE4.22 Multiplexer blockThis ‘Toolkit’ option block selects one of eight analogue inputs to appear at its output.Multiplexer.1High LimitLow LimitFall Back StrategyFall Back ValueInput SelectorInput 1Input 2Input 3Input 8PV OutStatusResolution100000000.0-100000000.0Clip bad0.0Input 10.00.00.00.00Ok0Figure 4.22 Multiplexer block configuration4.22.1 Configuration parametersHigh Limit The high limit for input, output and fallback values. Minimum value is Low Limit.Low LimitThe low limit for input and fallback values. Maximum value is High Limit.Fallback Strategy Clip Bad: If the input value is above ‘High Limit’ or below ‘Low Limit’, then the outputvalue is set to the appropriate limit, and the status is set to ‘Bad’. If the input signal iswithin the limits, but its status is bad, the output is set to the Fallback value.Clip Good: If the input value is above ‘High Limit’ or below ‘Low Limit’, then the outputvalue is set to the appropriate limit, and the status is set to ‘Good’. If the input signal iswithin the limits, but its status is bad, the output is set to the Fallback value.Fall Bad: If the input value is above ‘High Limit’ or below ‘Low Limit’, then the outputvalue is set to the Fallback value, and the status is set to ‘Bad’Fall Good: If the input value is above ‘High Limit’ or below ‘Low Limit’, then the outputvalue is set to the Fallback value, and the status is set to ‘Good’Upscale: If the input status is bad, or if the input signal is above ‘High Limit’ or below‘Low Limit’, the output value is set to the High limit.Downscale: If the input status is bad, or if the input signal is above ‘High Limit’ or below‘Low Limit’, the output value is set to the Low limit.Fallback Value The value to be adopted by the output, under error conditions, if ‘Fallback Status’ is setto ‘Fall Good’ or ‘Fall Bad’.Input Selector Selects which of the eight inputs is presented at the output. When wired to a suitableparameter, Input Selector becomes read only. Input 1 is selected for an Input Selectorvalue of 1, Input 2 for a value of 2 and so on. Input Selector values greater than 8 areignored. If not wired, the user may select the required input using the scroll keys.Input 1 to 8 Wired to the relevant analogue inputs.PV OutThe output from the multiplexer block.StatusIndicates the status of the operation as ‘Ok’ or ‘Error’.Resolution The number of decimal places for the output value (maximum = 6)Page 162HA030554Issue 7 Nov 12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!