11.07.2015 Views

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

nanodac RECORDER/CONTROLLER: USER GUIDEParameter path Description Type Hex Dec ResolutionVirtualChannel.10.Main.UnitsScaler Units scaler for totalisers float32 2083 8323 1dpVirtualChannel.10.Trend.Colour As VirtualChannel1.Trend.Colour uint8 20a0 8352 Not applicableVirtualChannel.10.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 20a2 8354 Same as VirtualChannel.10.Main.PVVirtualChannel.10.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 20a1 8353 Same as VirtualChannel.10.Main.PVVirtualChannel.11.Alarm1.Acknowledge 1 = acknowledge alarm bool 01d4 468 Not applicableVirtualChannel.11.Alarm1.Acknowledgement 1 = alarm acknowledged bool 2150 8528 Not applicableVirtualChannel.11.Alarm1.Active 1 = alarm source active, or safe but not ack’d bool 214b 8523 Not applicableVirtualChannel.11.Alarm1.Amount Rate-of-change alarm ‘Amount’ float32 2148 8520 Same as VirtualChannel.11.Main.PVVirtualChannel.11.Alarm1.AverageTime Rate-of-change alarm ‘Average time’ time_t 214a 8522 Set by Network.Modbus.TimeFormatVirtualChannel.11.Alarm1.Block 0 = Blocking alarms off; 1 = Blocking alarms on uint8 2142 8514 Not applicableVirtualChannel.11.Alarm1.ChangeTime Rate-of-change alarm ‘Change Time’ uint8 2149 8521 Not applicableVirtualChannel.11.Alarm1.Deviation Deviation alarm ‘Deviation Value’ float32 2147 8519 Same as VirtualChannel.11.Main.PVVirtualChannel.11.Alarm1.Dwell Alarm dwell time time_t 2145 8517 Set by Network.Modbus.TimeFormatVirtualChannel.11.Alarm1.Hysteresis Alarm hysteresis value float32 2144 8516 Same as VirtualChannel.11.Main.PVVirtualChannel.11.Alarm1.Inactive 1 = alarm source safe and ack’d (if necessary) bool 214e 8526 Not applicableVirtualChannel.11.Alarm1.Inhibit 1 = alarm inhibited bool 2151 8529 Not applicableVirtualChannel.11.Alarm1.Latch As VirtualChannel1.Alarm1.Latch uint8 2141 8513 Not applicableVirtualChannel.11.Alarm1.NotAcknowledged 1 = alarm has not been acknowledged bool 214f 8527 Not applicableVirtualChannel.11.Alarm1.Reference Deviation alarm ‘Reference’ value float32 2146 8518 Same as VirtualChannel.11.Main.PVVirtualChannel.11.Alarm1.Status As VirtualChannel1.Alarm1.Status uint8 014a 330 Not applicableVirtualChannel.11.Alarm1.Threshold Alarm trigger threshold float32 2143 8515 Same as VirtualChannel.11.Main.PVVirtualChannel.11.Alarm1.Type As VirtualChannel1.Alarm1.Type uint8 2140 8512 Not applicableVirtualChannel.11.Alarm2.Acknowledge 1 = acknowledge alarm bool 01d5 469 Not applicableVirtualChannel.11.Alarm2.Acknowledgement 1 = alarm acknowledged bool 2170 8560 Not applicableVirtualChannel.11.Alarm2.Active 1 = alarm source active, or safe but not ack’d bool 216b 8555 Not applicableVirtualChannel.11.Alarm2.Amount Rate-of-change alarm ‘Amount’ float32 2168 8552 Same as VirtualChannel.11.Main.PVVirtualChannel.11.Alarm2.AverageTime Rate-of-change alarm ‘Average time’ time_t 216a 8554 Set by Network.Modbus.TimeFormatVirtualChannel.11.Alarm2.Block 0 = Blocking alarms off; 1 = Blocking alarms on uint8 2162 8546 Not applicableVirtualChannel.11.Alarm2.ChangeTime Rate-of-change alarm ‘Change Time’ uint8 2169 8553 Not applicableVirtualChannel.11.Alarm2.Deviation Deviation alarm ‘Deviation Value’ float32 2167 8551 Same as VirtualChannel.11.Main.PVVirtualChannel.11.Alarm2.Dwell Alarm dwell time time_t 2165 8549 Set by Network.Modbus.TimeFormatVirtualChannel.11.Alarm2.Hysteresis Alarm hysteresis value float32 2164 8548 Same as VirtualChannel.11.Main.PVVirtualChannel.11.Alarm2.Inactive 1 = alarm source safe and ack’d (if necessary) bool 216e 8558 Not applicableVirtualChannel.11.Alarm2.Inhibit 1 = alarm inhibited bool 2171 8561 Not applicableVirtualChannel.11.Alarm2.Latch As VirtualChannel1.Alarm1.Latch uint8 2161 8545 Not applicableVirtualChannel.11.Alarm2.NotAcknowledged 1 = alarm has not been acknowledged bool 216f 8559 Not applicableVirtualChannel.11.Alarm2.Reference Deviation alarm ‘Reference’ value float32 2166 8550 Same as VirtualChannel.11.Main.PVVirtualChannel.11.Alarm2.Status As VirtualChannel1.Alarm1.Status uint8 014b 331 Not applicableVirtualChannel.11.Alarm2.Threshold Alarm trigger threshold float32 2163 8547 Same as VirtualChannel.11.Main.PVVirtualChannel.11.Alarm2.Type As VirtualChannel1.Alarm1.Type uint8 2160 8544 Not applicableVirtualChannel.11.Main.Descriptor Virtual Channel descriptor string_t 4c0e 19470 Not applicableVirtualChannel.11.Main.Disable 1 = Virtual channel disabled bool 2123 8483 Not applicableVirtualChannel.11.Main.HighCutOff The highest input value that will be totalised/counted float32 2105 8453 Set by VirtualChannel.11.Main.ResolutionVirtualChannel.11.Main.Input1 Input 1 value float32 2107 8455 Set by VirtualChannel.11.Main.ResolutionVirtualChannel.11.Main.Input2 Input 2 value float32 2108 8456 Set by VirtualChannel.11.Main.ResolutionVirtualChannel.11.Main.LowCutOff The lowest input value that will be totalised/counted float32 2104 8452 Set by VirtualChannel.11.Main.ResolutionVirtualChannel.11.Main.ModbusInput Modbus input value float32 2106 8454 Set by VirtualChannel.11.Main.ResolutionVirtualChannel.11.Main.Operation As VirtualChannel1.Main.Operation uint8 2101 8449 Not applicableVirtualChannel.11.Main.Period The time period over which the calculation is made int32 210a 8458 Not applicableVirtualChannel.11.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 210c 8460 Not applicableVirtualChannel.11.Main.PresetValue The Preset value float32 210d 8461 Set by VirtualChannel.11.Main.ResolutionVirtualChannel.11.Main.PV The virtual channel output value float32 0148 328 Set by VirtualChannel.11.Main.ResolutionVirtualChannel.11.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 210b 8459 Not applicableVirtualChannel.11.Main.Resolution Number of decimal places (0 to 6) uint8 2102 8450 Not applicableVirtualChannel.11.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 2111 8465 Not applicableVirtualChannel.11.Main.RolloverValue Rollover value float32 2112 8466 Set by VirtualChannel.11.Main.ResolutionVirtualChannel.11.Main.Status As VirtualChannel1.Main.Status uint8 0149 329 Not applicableVirtualChannel.11.Main.TimeRemaining Time remaining before the calculation is made time_t 2109 8457 Set by Network.Modbus.TimeFormatVirtualChannel.11.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes bool 210e 8462 Not applicableVirtualChannel.11.Main.Type As VirtualChannel1.Main.Type uint8 2100 8448 Not applicableVirtualChannel.11.Main.Units Units descriptor string_t 4c23 19491 Not applicableVirtualChannel.11.Main.UnitsScaler Units scaler for totalisers float32 2103 8451 1dpVirtualChannel.11.Trend.Colour As VirtualChannel1.Trend.Colour uint8 2120 8480 Not applicableVirtualChannel.11.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 2122 8482 Same as VirtualChannel.11.Main.PVVirtualChannel.11.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 2121 8481 Same as VirtualChannel.11.Main.PVVirtualChannel.12.Alarm1.Acknowledge 1 = acknowledge alarm bool 01d6 470 Not applicableVirtualChannel.12.Alarm1.Acknowledgement 1 = alarm acknowledged bool 21d0 8656 Not applicableVirtualChannel.12.Alarm1.Active 1 = alarm source active, or safe but not ack’d bool 21cb 8651 Not applicableVirtualChannel.12.Alarm1.Amount Rate-of-change alarm ‘Amount’ float32 21c8 8648 Same as VirtualChannel.12.Main.PVVirtualChannel.12.Alarm1.AverageTime Rate-of-change alarm ‘Average time’ time_t 21ca 8650 Set by Network.Modbus.TimeFormatVirtualChannel.12.Alarm1.Block 0 = Blocking alarms off; 1 = Blocking alarms on uint8 21c2 8642 Not applicableVirtualChannel.12.Alarm1.ChangeTime Rate-of-change alarm ‘Change Time’ uint8 21c9 8649 Not applicableVirtualChannel.12.Alarm1.Deviation Deviation alarm ‘Deviation Value’ float32 21c7 8647 Same as VirtualChannel.12.Main.PVVirtualChannel.12.Alarm1.Dwell Alarm dwell time time_t 21c5 8645 Set by Network.Modbus.TimeFormatVirtualChannel.12.Alarm1.Hysteresis Alarm hysteresis value float32 21c4 8644 Same as VirtualChannel.12.Main.PVVirtualChannel.12.Alarm1.Inactive 1 = alarm source safe and ack’d (if necessary) bool 21ce 8654 Not applicableVirtualChannel.12.Alarm1.Inhibit 1 = alarm inhibited bool 21d1 8657 Not applicableVirtualChannel.12.Alarm1.Latch As VirtualChannel1.Alarm1.Latch uint8 21c1 8641 Not applicableVirtualChannel.12.Alarm1.NotAcknowledged 1 = alarm has not been acknowledged bool 21cf 8655 Not applicablePage 247HA030554Issue 7 Nov 12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!