11.07.2015 Views

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

nanodac RECORDER/CONTROLLER: USER GUIDEParameter path Description Type Hex Dec ResolutionVirtualChannel.22.Main.Status As VirtualChannel1.Main.Status uint8 0169 361 Not applicableVirtualChannel.22.Main.TimeRemaining Time remaining before the calculation is made time_t 2509 9481 Set by Network.Modbus.TimeFormatVirtualChannel.22.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes bool 250e 9486 Not applicableVirtualChannel.22.Main.Type As VirtualChannel1.Main.Type uint8 2500 9472 Not applicableVirtualChannel.22.Main.Units Units descriptor string_t 4d4d 19789 Not applicableVirtualChannel.22.Main.UnitsScaler Units scaler for totalisers float32 2503 9475 1dpVirtualChannel.22.Trend.Colour As VirtualChannel1.Trend.Colour uint8 2620 9760 Not applicableVirtualChannel.22.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 2622 9762 Same as VirtualChannel.22.Main.PVVirtualChannel.22.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 2621 9761 Same as VirtualChannel.22.Main.PVVirtualChannel.23.Main.Descriptor Virtual Channel descriptor string_t 4d53 19795 Not applicableVirtualChannel.23.Main.Disable 1 = Virtual channel disabled bool 2663 9827 Not applicableVirtualChannel.23.Main.HighCutOff The highest input value that will be totalised/counted float32 2545 9541 Set by VirtualChannel.23.Main.ResolutionVirtualChannel.23.Main.Input1 Input 1 value float32 2547 9543 Set by VirtualChannel.23.Main.ResolutionVirtualChannel.23.Main.Input2 Input 2 value float32 2548 9544 Set by VirtualChannel.23.Main.ResolutionVirtualChannel.23.Main.LowCutOff The lowest input value that will be totalised/counted float32 2544 9540 Set by VirtualChannel.23.Main.ResolutionVirtualChannel.23.Main.ModbusInput Modbus input value float32 2546 9542 Set by VirtualChannel.23.Main.ResolutionVirtualChannel.23.Main.Operation Specifies the operation of the virtual channel uint8 2541 9537 Not applicableVirtualChannel.23.Main.Period The time period over which the calculation is made int32 254a 9546 Not applicableVirtualChannel.23.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 254c 9548 Not applicableVirtualChannel.23.Main.PresetValue Specifies the preset value float32 254d 9549 Set by VirtualChannel.23.Main.ResolutionVirtualChannel.23.Main.PV The virtual channel output value float32 016a 362 Set by VirtualChannel.23.Main.ResolutionVirtualChannel.23.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 254b 9547 Not applicableVirtualChannel.23.Main.Resolution Specifies the resolution/number of decimal places uint8 2542 9538 Not applicableVirtualChannel.23.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 2551 9553 Not applicableVirtualChannel.23.Main.RolloverValue Rollover value float32 2552 9554 Set by VirtualChannel.23.Main.ResolutionVirtualChannel.23.Main.Status As VirtualChannel1.Main.Status uint8 016b 363 Not applicableVirtualChannel.23.Main.TimeRemaining Time remaining before the calculation is made time_t 2549 9545 Set by Network.Modbus.TimeFormatVirtualChannel.23.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes bool 254e 9550 Not applicableVirtualChannel.23.Main.Type As VirtualChannel1.Main.Type uint8 2540 9536 Not applicableVirtualChannel.23.Main.Units Units descriptor string_t 4d68 19816 Not applicableVirtualChannel.23.Main.UnitsScaler Units scaler for totalisers float32 2543 9539 1dpVirtualChannel.23.Trend.Colour As VirtualChannel1.Trend.Colour uint8 2660 9824 Not applicableVirtualChannel.23.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 2662 9826 Same as VirtualChannel.23.Main.PVVirtualChannel.23.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 2661 9825 Same as VirtualChannel.23.Main.PVVirtualChannel.24.Main.Descriptor Virtual Channel descriptor string_t 4d6e 19822 Not applicableVirtualChannel.24.Main.Disable 1 = Virtual channel disabled bool 26a3 9891 Not applicableVirtualChannel.24.Main.HighCutOff The highest input value that will be totalised/counted float32 2585 9605 Set by VirtualChannel.24.Main.ResolutionVirtualChannel.24.Main.Input1 Input 1 value float32 2587 9607 Set by VirtualChannel.24.Main.ResolutionVirtualChannel.24.Main.Input2 Input 2 value float32 2588 9608 Set by VirtualChannel.24.Main.ResolutionVirtualChannel.24.Main.LowCutOff The lowest input value that will be totalised/counted float32 2584 9604 Set by VirtualChannel.24.Main.ResolutionVirtualChannel.24.Main.ModbusInput Modbus input value float32 2586 9606 Set by VirtualChannel.24.Main.ResolutionVirtualChannel.24.Main.Operation Specifies the operation of the virtual channel uint8 2581 9601 Not applicableVirtualChannel.24.Main.Period The time period over which the calculation is made int32 258a 9610 Not applicableVirtualChannel.24.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 258c 9612 Not applicableVirtualChannel.24.Main.PresetValue Specifies the preset value float32 258d 9613 Set by VirtualChannel.24.Main.ResolutionVirtualChannel.24.Main.PV The virtual channel output value float32 016c 364 Set by VirtualChannel.24.Main.ResolutionVirtualChannel.24.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 258b 9611 Not applicableVirtualChannel.24.Main.Resolution Specifies the resolution/number of decimal places uint8 2582 9602 Not applicableVirtualChannel.24.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 2591 9617 Not applicableVirtualChannel.24.Main.RolloverValue Rollover value float32 2592 9618 Set by VirtualChannel.24.Main.ResolutionVirtualChannel.24.Main.Status As VirtualChannel1.Main.Status uint8 016d 365 Not applicableVirtualChannel.24.Main.TimeRemaining Time remaining before the calculation is made time_t 2589 9609 Set by Network.Modbus.TimeFormatVirtualChannel.24.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes bool 258e 9614 Not applicableVirtualChannel.24.Main.Type As VirtualChannel1.Main.Type uint8 2580 9600 Not applicableVirtualChannel.24.Main.Units Units descriptor string_t 4d83 19843 Not applicableVirtualChannel.24.Main.UnitsScaler Units scaler for totalisers float32 2583 9603 1dpVirtualChannel.24.Trend.Colour As VirtualChannel1.Trend.Colour uint8 26a0 9888 Not applicableVirtualChannel.24.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 26a2 9890 Same as VirtualChannel.24.Main.PVVirtualChannel.24.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 26a1 9889 Same as VirtualChannel.24.Main.PVVirtualChannel.25.Main.Descriptor Virtual Channel descriptor string_t 4d89 19849 Not applicableVirtualChannel.25.Main.Disable 1 = Virtual channel disabled bool 26e3 9955 Not applicableVirtualChannel.25.Main.HighCutOff The highest input value that will be totalised/counted float32 25c5 9669 Set by VirtualChannel.25.Main.ResolutionVirtualChannel.25.Main.Input1 Input 1 value float32 25c7 9671 Set by VirtualChannel.25.Main.ResolutionVirtualChannel.25.Main.Input2 Input 2 value float32 25c8 9672 Set by VirtualChannel.25.Main.ResolutionVirtualChannel.25.Main.LowCutOff The lowest input value that will be totalised/counted float32 25c4 9668 Set by VirtualChannel.25.Main.ResolutionVirtualChannel.25.Main.ModbusInput Modbus input value float32 25c6 9670 Set by VirtualChannel.25.Main.ResolutionVirtualChannel.25.Main.Operation Specifies the operation of the virtual channel uint8 25c1 9665 Not applicableVirtualChannel.25.Main.Period The time period over which the calculation is made int32 25ca 9674 Not applicableVirtualChannel.25.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 25cc 9676 Not applicableVirtualChannel.25.Main.PresetValue Specifies the preset value float32 25cd 9677 Set by VirtualChannel.25.Main.ResolutionVirtualChannel.25.Main.PV The virtual channel output value float32 016e 366 Set by VirtualChannel.25.Main.ResolutionVirtualChannel.25.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 25cb 9675 Not applicableVirtualChannel.25.Main.Resolution Specifies the resolution/number of decimal places uint8 25c2 9666 Not applicableVirtualChannel.25.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 25d1 9681 Not applicableVirtualChannel.25.Main.RolloverValue Rollover value float32 25d2 9682 Set by VirtualChannel.25.Main.ResolutionVirtualChannel.25.Main.Status As VirtualChannel1.Main.Status uint8 016f 367 Not applicableVirtualChannel.25.Main.TimeRemaining Time remaining before the calculation is made time_t 25c9 9673 Set by Network.Modbus.TimeFormatVirtualChannel.25.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes bool 25ce 9678 Not applicableHA030554Issue 7 Nov 12Page 253

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!