11.07.2015 Views

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

nanodac RECORDER/CONTROLLER: USER GUIDEParameter path Description Type Hex Dec ResolutionVirtualChannel.19.Main.Resolution Specifies the resolution/number of decimal places uint8 2442 9282 Not applicableVirtualChannel.19.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 2451 9297 Not applicableVirtualChannel.19.Main.RolloverValue Rollover value float32 2452 9298 Set by VirtualChannel.19.Main.ResolutionVirtualChannel.19.Main.Status TAs VirtualChannel1.Main.Statusv uint8 0163 355 Not applicableVirtualChannel.19.Main.TimeRemaining Time remaining before the calculation is made time_t 2449 9289 Set by Network.Modbus.TimeFormatVirtualChannel.19.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes bool 244e 9294 Not applicableVirtualChannel.19.Main.Type As VirtualChannel1.Main.Type uint8 2440 9280 Not applicableVirtualChannel.19.Main.Units Units descriptor string_t 4cfc 19708 Not applicableVirtualChannel.19.Main.UnitsScaler Units scaler for totalisers float32 2443 9283 1dpVirtualChannel.19.Trend.Colour As VirtualChannel1.Trend.Colour uint8 2560 9568 Not applicableVirtualChannel.19.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 2562 9570 Same as VirtualChannel.19.Main.PVVirtualChannel.19.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 2561 9569 Same as VirtualChannel.19.Main.PVVirtualChannel.20.Main.Descriptor Virtual Channel descriptor string_t 4d02 19714 Not applicableVirtualChannel.20.Main.Disable 1 = Virtual channel disabled bool 25a3 9635 Not applicableVirtualChannel.20.Main.HighCutOff The highest input value that will be totalised/counted float32 2485 9349 Set by VirtualChannel.20.Main.ResolutionVirtualChannel.20.Main.Input1 Input 1 value float32 2487 9351 Set by VirtualChannel.20.Main.ResolutionVirtualChannel.20.Main.Input2 Input 2 value float32 2488 9352 Set by VirtualChannel.20.Main.ResolutionVirtualChannel.20.Main.LowCutOff The lowest input value that will be totalised/counted float32 2484 9348 Set by VirtualChannel.20.Main.ResolutionVirtualChannel.20.Main.ModbusInput Modbus input value float32 2486 9350 Set by VirtualChannel.20.Main.ResolutionVirtualChannel.20.Main.Operation Specifies the operation of the virtual channel uint8 2481 9345 Not applicableVirtualChannel.20.Main.Period The time period over which the calculation is made int32 248a 9354 Not applicableVirtualChannel.20.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 248c 9356 Not applicableVirtualChannel.20.Main.PresetValue Specifies the preset value float32 248d 9357 Set by VirtualChannel.20.Main.ResolutionVirtualChannel.20.Main.PV The virtual channel output value float32 0164 356 Set by VirtualChannel.20.Main.ResolutionVirtualChannel.20.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 248b 9355 Not applicableVirtualChannel.20.Main.Resolution Specifies the resolution/number of decimal places uint8 2482 9346 Not applicableVirtualChannel.20.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 2491 9361 Not applicableVirtualChannel.20.Main.RolloverValue Rollover value float32 2492 9362 Set by VirtualChannel.20.Main.ResolutionVirtualChannel.20.Main.Status As VirtualChannel1.Main.Status uint8 0165 357 Not applicableVirtualChannel.20.Main.TimeRemaining Time remaining before the calculation is made time_t 2489 9353 Set by Network.Modbus.TimeFormatVirtualChannel.20.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes bool 248e 9358 Not applicableVirtualChannel.20.Main.Type As VirtualChannel1.Main.Type uint8 2480 9344 Not applicableVirtualChannel.20.Main.Units Units descriptor string_t 4d17 19735 Not applicableVirtualChannel.20.Main.UnitsScaler Units scaler for totalisers float32 2483 9347 1dpVirtualChannel.20.Trend.Colour As VirtualChannel1.Trend.Colour uint8 25a0 9632 Not applicableVirtualChannel.20.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 25a2 9634 Same as VirtualChannel.20.Main.PVVirtualChannel.20.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 25a1 9633 Same as VirtualChannel.20.Main.PVVirtualChannel.21.Main.Descriptor Virtual Channel descriptor string_t 4d1d 19741 Not applicableVirtualChannel.21.Main.Disable 1 = Virtual channel disabled bool 25e3 9699 Not applicableVirtualChannel.21.Main.HighCutOff The highest input value that will be totalised/counted float32 24c5 9413 Set by VirtualChannel.21.Main.ResolutionVirtualChannel.21.Main.Input1 Input 1 value float32 24c7 9415 Set by VirtualChannel.21.Main.ResolutionVirtualChannel.21.Main.Input2 Input 2 value float32 24c8 9416 Set by VirtualChannel.21.Main.ResolutionVirtualChannel.21.Main.LowCutOff The lowest input value that will be totalised/counted float32 24c4 9412 Set by VirtualChannel.21.Main.ResolutionVirtualChannel.21.Main.ModbusInput Modbus input value float32 24c6 9414 Set by VirtualChannel.21.Main.ResolutionVirtualChannel.21.Main.Operation Specifies the operation of the virtual channel uint8 24c1 9409 Not applicableVirtualChannel.21.Main.Period The time period over which the calculation is made int32 24ca 9418 Not applicableVirtualChannel.21.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 24cc 9420 Not applicableVirtualChannel.21.Main.PresetValue Specifies the preset value float32 24cd 9421 Set by VirtualChannel.21.Main.ResolutionVirtualChannel.21.Main.PV The virtual channel output value float32 0166 358 Set by VirtualChannel.21.Main.ResolutionVirtualChannel.21.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 24cb 9419 Not applicableVirtualChannel.21.Main.Resolution Specifies the resolution/number of decimal places uint8 24c2 9410 Not applicableVirtualChannel.21.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 24d1 9425 Not applicableVirtualChannel.21.Main.RolloverValue Rollover value float32 24d2 9426 Set by VirtualChannel.21.Main.ResolutionVirtualChannel.21.Main.Status As VirtualChannel1.Main.Status uint8 0167 359 Not applicableVirtualChannel.21.Main.TimeRemaining Time remaining before the calculation is made time_t 24c9 9417 Set by Network.Modbus.TimeFormatVirtualChannel.21.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes bool 24ce 9422 Not applicableVirtualChannel.21.Main.Type As VirtualChannel1.Main.Type uint8 24c0 9408 Not applicableVirtualChannel.21.Main.Units Units descriptor string_t 4d32 19762 Not applicableVirtualChannel.21.Main.UnitsScaler Units scaler for totalisers float32 24c3 9411 1dpVirtualChannel.21.Trend.Colour As VirtualChannel1.Trend.Colour uint8 25e0 9696 Not applicableVirtualChannel.21.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 25e2 9698 Same as VirtualChannel.21.Main.PVVirtualChannel.21.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 25e1 9697 Same as VirtualChannel.21.Main.PVVirtualChannel.22.Main.Descriptor Virtual Channel descriptor string_t 4d38 19768 Not applicableVirtualChannel.22.Main.Disable 1 = Virtual channel disabled bool 2623 9763 Not applicableVirtualChannel.22.Main.HighCutOff The highest input value that will be totalised/counted float32 2505 9477 Set by VirtualChannel.22.Main.ResolutionVirtualChannel.22.Main.Input1 Input 1 value float32 2507 9479 Set by VirtualChannel.22.Main.ResolutionVirtualChannel.22.Main.Input2 Input 2 value float32 2508 9480 Set by VirtualChannel.22.Main.ResolutionVirtualChannel.22.Main.LowCutOff The lowest input value that will be totalised/counted float32 2504 9476 Set by VirtualChannel.22.Main.ResolutionVirtualChannel.22.Main.ModbusInput Modbus input value float32 2506 9478 Set by VirtualChannel.22.Main.ResolutionVirtualChannel.22.Main.Operation Specifies the operation of the virtual channel uint8 2501 9473 Not applicableVirtualChannel.22.Main.Period The time period over which the calculation is made int32 250a 9482 Not applicableVirtualChannel.22.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 250c 9484 Not applicableVirtualChannel.22.Main.PresetValue Specifies the preset value float32 250d 9485 Set by VirtualChannel.22.Main.ResolutionVirtualChannel.22.Main.PV The virtual channel output value float32 0168 360 Set by VirtualChannel.22.Main.ResolutionVirtualChannel.22.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 250b 9483 Not applicableVirtualChannel.22.Main.Resolution Specifies the resolution/number of decimal places uint8 2502 9474 Not applicableVirtualChannel.22.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 2511 9489 Not applicableVirtualChannel.22.Main.RolloverValue Rollover value float32 2512 9490 Set by VirtualChannel.22.Main.ResolutionPage 252HA030554Issue 7 Nov 12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!