11.07.2015 Views

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

nanodac RECORDER/CONTROLLER: USER GUIDEParameter path Description Type Hex Dec Resolution6 = Dark blue 7 = Jade 8 = Magenta9 = Dusky rose 10 = Yellow 11 = Powder blue12 = Dark red 13 = Avocado 14 = Indigo15 = Dark brown 16 = Aegean 17 = Cyan18 = Aubergine 19 = Dark orange 20 = Pale yellow21 = Hyacinth 22 = Dark green 23 = Sugar pink24 = Bluebell 25 = Orange 26 = Pink27 = Buttersilk 28 = Terracotta 29 = Blue babe30 = Lime 31 = Blue jive 32 = Cucumber33 = Eurogreen 34 = Wheatgerm 35 = Sea Blue36 = Ginger 37 = Aqua pool 38 = Pale red39 = Pale blue 40 = Lilac 41 = Sky blue42 = Wild moss 43 = Turquoise 44 = Pale green45 = Coffee 49 = Dark Grey 53 = Light greyVirtualChannel.1.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 1c22 7202 Same as VirtualChannel.1.Main.PVVirtualChannel.1.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 1c21 7201 Same as VirtualChannel.1.Main.PVVirtualChannel.2.Alarm1.Acknowledge 1 = acknowledge alarm bool 01c2 450 Not applicableVirtualChannel.2.Alarm1.Acknowledgement 1 = alarm acknowledged bool 1cd0 7376 Not applicableVirtualChannel.2.Alarm1.Active 1 = alarm source active, or safe but not ack’d bool 1ccb 7371 Not applicableVirtualChannel.2.Alarm1.Amount Rate-of-change alarm ‘Amount’ float32 1cc8 7368 Same as VirtualChannel.2.Main.PVVirtualChannel.2.Alarm1.AverageTime Rate-of-change alarm ‘Average time’ time_t 1cca 7370 Set by Network.Modbus.TimeFormatVirtualChannel.2.Alarm1.Block 0 = Blocking alarms off; 1 = Blocking alarms on uint8 1cc2 7362 Not applicableVirtualChannel.2.Alarm1.ChangeTime Rate-of-change alarm ‘Change Time’ uint8 1cc9 7369 Not applicableVirtualChannel.2.Alarm1.Deviation Deviation alarm ‘Deviation Value’ float32 1cc7 7367 Same as VirtualChannel.2.Main.PVVirtualChannel.2.Alarm1.Dwell Alarm dwell time time_t 1cc5 7365 Set by Network.Modbus.TimeFormatVirtualChannel.2.Alarm1.Hysteresis Alarm hysteresis value float32 1cc4 7364 Same as VirtualChannel.2.Main.PVVirtualChannel.2.Alarm1.Inactive 1 = alarm source safe and ack’d (if necessary) bool 1cce 7374 Not applicableVirtualChannel.2.Alarm1.Inhibit 1 = alarm inhibited bool 1cd1 7377 Not applicableVirtualChannel.2.Alarm1.Latch As VirtualChannel1.Alarm1.Latch uint8 1cc1 7361 Not applicableVirtualChannel.2.Alarm1.NotAcknowledged 1 = alarm has not been acknowledged bool 1ccf 7375 Not applicableVirtualChannel.2.Alarm1.Reference Deviation alarm ‘Reference’ value float32 1cc6 7366 Same as VirtualChannel.2.Main.PVVirtualChannel.2.Alarm1.Status As VirtualChannel1.Alarm1.Status uint8 0126 294 Not applicableVirtualChannel.2.Alarm1.Threshold Alarm trigger threshold float32 1cc3 7363 Same as VirtualChannel.2.Main.PVVirtualChannel.2.Alarm1.Type As VirtualChannel1.Alarm1.Type uint8 1cc0 7360 Not applicableVirtualChannel.2.Alarm2.Acknowledge 1 = acknowledge alarm bool 01c3 451 Not applicableVirtualChannel.2.Alarm2.Acknowledgement 1 = alarm acknowledged bool 1cf0 7408 Not applicableVirtualChannel.2.Alarm2.Active 1 = alarm source active, or safe but not ack’d bool 1ceb 7403 Not applicableVirtualChannel.2.Alarm2.Amount Rate-of-change alarm ‘Amount’ float32 1ce8 7400 Same as VirtualChannel.2.Main.PVVirtualChannel.2.Alarm2.AverageTime Rate-of-change alarm ‘Average time’ time_t 1cea 7402 Set by Network.Modbus.TimeFormatVirtualChannel.2.Alarm2.Block 0 = Blocking alarms off; 1 = Blocking alarms on uint8 1ce2 7394 Not applicableVirtualChannel.2.Alarm2.ChangeTime Rate-of-change alarm ‘Change Time’ uint8 1ce9 7401 Not applicableVirtualChannel.2.Alarm2.Deviation Deviation alarm ‘Deviation Value’ float32 1ce7 7399 Same as VirtualChannel.2.Main.PVVirtualChannel.2.Alarm2.Dwell Alarm dwell time time_t 1ce5 7397 Set by Network.Modbus.TimeFormatVirtualChannel.2.Alarm2.Hysteresis Alarm hysteresis value float32 1ce4 7396 Same as VirtualChannel.2.Main.PVVirtualChannel.2.Alarm2.Inactive 1 = alarm source safe and ack’d (if necessary) bool 1cee 7406 Not applicableVirtualChannel.2.Alarm2.Inhibit 1 = alarm inhibited bool 1cf1 7409 Not applicableVirtualChannel.2.Alarm2.Latch As VirtualChannel1.Alarm1.Latch uint8 1ce1 7393 Not applicableVirtualChannel.2.Alarm2.NotAcknowledged 1 = alarm has not been acknowledged bool 1cef 7407 Not applicableVirtualChannel.2.Alarm2.Reference Deviation alarm ‘Reference’ value float32 1ce6 7398 Same as VirtualChannel.2.Main.PVVirtualChannel.2.Alarm2.Status As VirtualChannel1.Alarm1.Status uint8 0127 295 Not applicableVirtualChannel.2.Alarm2.Threshold Alarm trigger threshold float32 1ce3 7395 Same as VirtualChannel.2.Main.PVVirtualChannel.2.Alarm2.Type As VirtualChannel1.Alarm1.Type uint8 1ce0 7392 Not applicableVirtualChannel.2.Main.Descriptor Virtual Channel descriptor string_t 4b1b 19227 Not applicableVirtualChannel.2.Main.Disable 1 = Virtual channel disabled bool 1ca3 7331 Not applicableVirtualChannel.2.Main.HighCutOff The highest input value that will be totalised/counted float32 1c85 7301 Set by VirtualChannel.2.Main.ResolutionVirtualChannel.2.Main.Input1 Input 1 value float32 1c87 7303 Set by VirtualChannel.2.Main.ResolutionVirtualChannel.2.Main.Input2 Input 2 value float32 1c88 7304 Set by VirtualChannel.2.Main.ResolutionVirtualChannel.2.Main.LowCutOff The lowest input value that will be totalised/counted float32 1c84 7300 Set by VirtualChannel.2.Main.ResolutionVirtualChannel.2.Main.ModbusInput Modbus input value float32 1c86 7302 Set by VirtualChannel.2.Main.ResolutionVirtualChannel.2.Main.Operation As VirtualChannel1.Main.Operation uint8 1c81 7297 Not applicableVirtualChannel.2.Main.Period The time period over which the calculation is made int32 1c8a 7306 Not applicableVirtualChannel.2.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 1c8c 7308 Not applicableVirtualChannel.2.Main.PresetValue The Preset value float32 1c8d 7309 Set by VirtualChannel.2.Main.ResolutionVirtualChannel.2.Main.PV The virtual channel output value float32 0124 292 Set by VirtualChannel.2.Main.ResolutionVirtualChannel.2.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 1c8b 7307 Not applicableVirtualChannel.2.Main.Resolution Specifies the resolution/number of decimal places uint8 1c82 7298 Not applicableVirtualChannel.2.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 1c91 7313 Not applicableVirtualChannel.2.Main.RolloverValue Rollover value float32 1c92 7314 Set by VirtualChannel.2.Main.ResolutionVirtualChannel.2.Main.Status As VirtualChannel1.Main.Status uint8 0125 293 Not applicableVirtualChannel.2.Main.TimeRemaining Time remaining before the calculation is made time_t 1c89 7305 Set by Network.Modbus.TimeFormatVirtualChannel.2.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes bool 1c8e 7310 Not applicableVirtualChannel.2.Main.Type As VirtualChannel1.Main.Type uint8 1c80 7296 Not applicableVirtualChannel.2.Main.Units Units descriptor string_t 4b30 19248 Not applicableVirtualChannel.2.Main.UnitsScaler Units scaler for totalisers float32 1c83 7299 1dpVirtualChannel.2.Trend.Colour As VirtualChannel1.Trend.Colour uint8 1ca0 7328 Not applicableVirtualChannel.2.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 1ca2 7330 Same as VirtualChannel.2.Main.PVVirtualChannel.2.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 1ca1 7329 Same as VirtualChannel.2.Main.PVVirtualChannel.3.Alarm1.Acknowledge 1 = acknowledge alarm bool 01c4 452 Not applicableVirtualChannel.3.Alarm1.Acknowledgement 1 = alarm acknowledged bool 1d50 7504 Not applicableHA030554Issue 7 Nov 12Page 240

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!