11.07.2015 Views

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

nanodac RECORDER/CONTROLLER: USER GUIDEParameter path Description Type Hex Dec ResolutionVirtualChannel.13.Alarm2.Status As VirtualChannel1.Alarm1.Status uint8 0153 339 Not applicableVirtualChannel.13.Alarm2.Threshold Alarm trigger threshold float32 2263 8803 Same as VirtualChannel.13.Main.PVVirtualChannel.13.Alarm2.Type As VirtualChannel1.Alarm1.Type uint8 2260 8800 Not applicableVirtualChannel.13.Main.Descriptor Virtual Channel descriptor string_t 4c44 19524 Not applicableVirtualChannel.13.Main.Disable 1 = Virtual channel disabled bool 2223 8739 Not applicableVirtualChannel.13.Main.HighCutOff The highest input value that will be totalised/counted float32 2205 8709 Set by VirtualChannel.13.Main.ResolutionVirtualChannel.13.Main.Input1 Input 1 value float32 2207 8711 Set by VirtualChannel.13.Main.ResolutionVirtualChannel.13.Main.Input2 Input 2 value float32 2208 8712 Set by VirtualChannel.13.Main.ResolutionVirtualChannel.13.Main.LowCutOff The lowest input value that will be totalised/counted float32 2204 8708 Set by VirtualChannel.13.Main.ResolutionVirtualChannel.13.Main.ModbusInput Modbus input value float32 2206 8710 Set by VirtualChannel.13.Main.ResolutionVirtualChannel.13.Main.Operation As VirtualChannel1.Main.Operation uint8 2201 8705 Not applicableVirtualChannel.13.Main.Period The time period over which the calculation is made int32 220a 8714 Not applicableVirtualChannel.13.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 220c 8716 Not applicableVirtualChannel.13.Main.PresetValue The Preset value float32 220d 8717 Set by VirtualChannel.13.Main.ResolutionVirtualChannel.13.Main.PV The virtual channel output value float32 0150 336 Set by VirtualChannel.13.Main.ResolutionVirtualChannel.13.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 220b 8715 Not applicableVirtualChannel.13.Main.Resolution Number of decimal places (0 to 6) uint8 2202 8706 Not applicableVirtualChannel.13.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 2211 8721 Not applicableVirtualChannel.13.Main.RolloverValue Rollover value float32 2212 8722 Set by VirtualChannel.13.Main.ResolutionVirtualChannel.13.Main.Status As VirtualChannel1.Main.Status uint8 0151 337 Not applicableVirtualChannel.13.Main.TimeRemaining Time remaining before the calculation is made time_t 2209 8713 Set by Network.Modbus.TimeFormatVirtualChannel.13.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes bool 220e 8718 Not applicableVirtualChannel.13.Main.Type As VirtualChannel1.Main.Type uint8 2200 8704 Not applicableVirtualChannel.13.Main.Units Units descriptor string_t 4c59 19545 Not applicableVirtualChannel.13.Main.UnitsScaler Units scaler for totalisers float32 2203 8707 1dpVirtualChannel.13.Trend.Colour As VirtualChannel1.Trend.Colour uint8 2220 8736 Not applicableVirtualChannel.13.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 2222 8738 Same as VirtualChannel.13.Main.PVVirtualChannel.13.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 2221 8737 Same as VirtualChannel.13.Main.PVVirtualChannel.14.Alarm1.Acknowledge 1 = acknowledge alarm bool 01da 474 Not applicableVirtualChannel.14.Alarm1.Acknowledgement 1 = alarm acknowledged bool 22d0 8912 Not applicableVirtualChannel.14.Alarm1.Active 1 = alarm source active, or safe but not ack’d bool 22cb 8907 Not applicableVirtualChannel.14.Alarm1.Amount Rate-of-change alarm ‘Amount’ float32 22c8 8904 Same as VirtualChannel.14.Main.PVVirtualChannel.14.Alarm1.AverageTime Rate-of-change alarm ‘Average time’ time_t 22ca 8906 Set by Network.Modbus.TimeFormatVirtualChannel.14.Alarm1.Block 0 = Blocking alarms off; 1 = Blocking alarms on uint8 22c2 8898 Not applicableVirtualChannel.14.Alarm1.ChangeTime Rate-of-change alarm ‘Change Time’ uint8 22c9 8905 Not applicableVirtualChannel.14.Alarm1.Deviation Deviation alarm ‘Deviation Value’ float32 22c7 8903 Same as VirtualChannel.14.Main.PVVirtualChannel.14.Alarm1.Dwell Alarm dwell time time_t 22c5 8901 Set by Network.Modbus.TimeFormatVirtualChannel.14.Alarm1.Hysteresis Alarm hysteresis value float32 22c4 8900 Same as VirtualChannel.14.Main.PVVirtualChannel.14.Alarm1.Inactive 1 = alarm source safe and ack’d (if necessary) bool 22ce 8910 Not applicableVirtualChannel.14.Alarm1.Inhibit 1 = alarm inhibited bool 22d1 8913 Not applicableVirtualChannel.14.Alarm1.Latch As VirtualChannel1.Alarm1.Latch uint8 22c1 8897 Not applicableVirtualChannel.14.Alarm1.NotAcknowledged 1 = alarm has not been acknowledged bool 22cf 8911 Not applicableVirtualChannel.14.Alarm1.Reference Deviation alarm ‘Reference’ value float32 22c6 8902 Same as VirtualChannel.14.Main.PVVirtualChannel.14.Alarm1.Status As VirtualChannel1.Alarm1.Status uint8 0156 342 Not applicableVirtualChannel.14.Alarm1.Threshold Alarm trigger threshold float32 22c3 8899 Same as VirtualChannel.14.Main.PVVirtualChannel.14.Alarm1.Type As VirtualChannel1.Alarm1.Type uint8 22c0 8896 Not applicableVirtualChannel.14.Alarm2.Acknowledge 1 = acknowledge alarm bool 01db 475 Not applicableVirtualChannel.14.Alarm2.Acknowledgement 1 = alarm acknowledged bool 22f0 8944 Not applicableVirtualChannel.14.Alarm2.Active 1 = alarm source active, or safe but not ack’d bool 22eb 8939 Not applicableVirtualChannel.14.Alarm2.Amount Rate-of-change alarm ‘Amount’ float32 22e8 8936 Same as VirtualChannel.14.Main.PVVirtualChannel.14.Alarm2.AverageTime Rate-of-change alarm ‘Average time’ time_t 22ea 8938 Set by Network.Modbus.TimeFormatVirtualChannel.14.Alarm2.Block 0 = Blocking alarms off; 1 = Blocking alarms on uint8 22e2 8930 Not applicableVirtualChannel.14.Alarm2.ChangeTime Rate-of-change alarm ‘Change Time’ uint8 22e9 8937 Not applicableVirtualChannel.14.Alarm2.Deviation Deviation alarm ‘Deviation Value’ float32 22e7 8935 Same as VirtualChannel.14.Main.PVVirtualChannel.14.Alarm2.Dwell Alarm dwell time time_t 22e5 8933 Set by Network.Modbus.TimeFormatVirtualChannel.14.Alarm2.Hysteresis Alarm hysteresis value float32 22e4 8932 Same as VirtualChannel.14.Main.PVVirtualChannel.14.Alarm2.Inactive 1 = alarm source safe and ack’d (if necessary) bool 22ee 8942 Not applicableVirtualChannel.14.Alarm2.Inhibit 1 = alarm inhibited bool 22f1 8945 Not applicableVirtualChannel.14.Alarm2.Latch As VirtualChannel1.Alarm1.Latch uint8 22e1 8929 Not applicableVirtualChannel.14.Alarm2.NotAcknowledged 1 = alarm has not been acknowledged bool 22ef 8943 Not applicableVirtualChannel.14.Alarm2.Reference Deviation alarm ‘Reference’ value float32 22e6 8934 Same as VirtualChannel.14.Main.PVVirtualChannel.14.Alarm2.Status As VirtualChannel1.Alarm1.Status uint8 0157 343 Not applicableVirtualChannel.14.Alarm2.Threshold Alarm trigger threshold float32 22e3 8931 Same as VirtualChannel.14.Main.PVVirtualChannel.14.Alarm2.Type As VirtualChannel1.Alarm1.Type uint8 22e0 8928 Not applicableVirtualChannel.14.Main.Descriptor Virtual Channel descriptor string_t 4c5f 19551 Not applicableVirtualChannel.14.Main.Disable 1 = Virtual channel disabled bool 22a3 8867 Not applicableVirtualChannel.14.Main.HighCutOff The highest input value that will be totalised/counted float32 2285 8837 Set by VirtualChannel.14.Main.ResolutionVirtualChannel.14.Main.Input1 Input 1 value float32 2287 8839 Set by VirtualChannel.14.Main.ResolutionVirtualChannel.14.Main.Input2 Input 2 value float32 2288 8840 Set by VirtualChannel.14.Main.ResolutionVirtualChannel.14.Main.LowCutOff The lowest input value that will be totalised/counted float32 2284 8836 Set by VirtualChannel.14.Main.ResolutionVirtualChannel.14.Main.ModbusInput Modbus input value float32 2286 8838 Set by VirtualChannel.14.Main.ResolutionVirtualChannel.14.Main.Operation As VirtualChannel1.Main.Operation uint8 2281 8833 Not applicableVirtualChannel.14.Main.Period The time period over which the calculation is made int32 228a 8842 Not applicableVirtualChannel.14.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 228c 8844 Not applicableVirtualChannel.14.Main.PresetValue The preset value float32 228d 8845 Set by VirtualChannel.14.Main.ResolutionVirtualChannel.14.Main.PV The virtual channel output value float32 0154 340 Set by VirtualChannel.14.Main.ResolutionVirtualChannel.14.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 228b 8843 Not applicableVirtualChannel.14.Main.Resolution Number of decimal places (0 to 6) uint8 2282 8834 Not applicableVirtualChannel.14.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 2291 8849 Not applicableVirtualChannel.14.Main.RolloverValue Rollover value float32 2292 8850 Set by VirtualChannel.14.Main.ResolutionPage 249HA030554Issue 7 Nov 12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!