11.07.2015 Views

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

User Guide - Eurotherm Ltda

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

nanodac RECORDER/CONTROLLER: USER GUIDEParameter path Description Type Hex Dec ResolutionVirtualChannel.9.Main.HighCutOff The highest input value that will be totalised/counted float32 2005 8197 Set by VirtualChannel.9.Main.ResolutionVirtualChannel.9.Main.Input1 Input 1 value float32 2007 8199 Set by VirtualChannel.9.Main.ResolutionVirtualChannel.9.Main.Input2 Input 2 value float32 2008 8200 Set by VirtualChannel.9.Main.ResolutionVirtualChannel.9.Main.LowCutOff The lowest input value that will be totalised/counted float32 2004 8196 Set by VirtualChannel.9.Main.ResolutionVirtualChannel.9.Main.ModbusInput Modbus input value float32 2006 8198 Set by VirtualChannel.9.Main.ResolutionVirtualChannel.9.Main.Operation As VirtualChannel1.Main.Operation uint8 2001 8193 Not applicableVirtualChannel.9.Main.Period The time period over which the calculation is made int32 200a 8202 Not applicableVirtualChannel.9.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 200c 8204 Not applicableVirtualChannel.9.Main.PresetValue The Preset value float32 200d 8205 Set by VirtualChannel.9.Main.ResolutionVirtualChannel.9.Main.PV The virtual channel output value float32 0140 320 Set by VirtualChannel.9.Main.ResolutionVirtualChannel.9.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 200b 8203 Not applicableVirtualChannel.9.Main.Resolution Number of decimal places (0 to 6) uint8 2002 8194 Not applicableVirtualChannel.9.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 2011 8209 Not applicableVirtualChannel.9.Main.RolloverValue Rollover value float32 2012 8210 Set by VirtualChannel.9.Main.ResolutionVirtualChannel.9.Main.Status As VirtualChannel1.Main.Status uint8 0141 321 Not applicableVirtualChannel.9.Main.TimeRemaining Time remaining before the calculation is made time_t 2009 8201 Set by Network.Modbus.TimeFormatVirtualChannel.9.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes bool 200e 8206 Not applicableVirtualChannel.9.Main.Type As VirtualChannel1.Main.Type uint8 2000 8192 Not applicableVirtualChannel.9.Main.Units Units descriptor string_t 4bed 19437 Not applicableVirtualChannel.9.Main.UnitsScaler Units scaler for totalisers float32 2003 8195 1dpVirtualChannel.9.Trend.Colour As VirtualChannel1.Trend.Colour uint8 2020 8224 Not applicableVirtualChannel.9.Trend.SpanHigh Specifies the highest PV (output value) to be displayed float32 2022 8226 Same as VirtualChannel.9.Main.PVVirtualChannel.9.Trend.SpanLow Specifies the lowest PV (output value) to be displayed float32 2021 8225 Same as VirtualChannel.9.Main.PVVirtualChannel.10.Alarm1.Acknowledge 1 = acknowledge alarm bool 01d2 466 Not applicableVirtualChannel.10.Alarm1.Acknowledgement 1 = alarm acknowledged bool 20d0 8400 Not applicableVirtualChannel.10.Alarm1.Active 1 = alarm source active, or safe but not ack’d bool 20cb 8395 Not applicableVirtualChannel.10.Alarm1.Amount Rate-of-change alarm ‘Amount’ float32 20c8 8392 Same as VirtualChannel.10.Main.PVVirtualChannel.10.Alarm1.AverageTime Rate-of-change alarm ‘Average time’ time_t 20ca 8394 Set by Network.Modbus.TimeFormatVirtualChannel.10.Alarm1.Block 0 = Blocking alarms off; 1 = Blocking alarms on uint8 20c2 8386 Not applicableVirtualChannel.10.Alarm1.ChangeTime Rate-of-change alarm ‘Change Time’ uint8 20c9 8393 Not applicableVirtualChannel.10.Alarm1.Deviation Deviation alarm ‘Deviation Value’ float32 20c7 8391 Same as VirtualChannel.10.Main.PVVirtualChannel.10.Alarm1.Dwell Alarm dwell time time_t 20c5 8389 Set by Network.Modbus.TimeFormatVirtualChannel.10.Alarm1.Hysteresis Alarm hysteresis value float32 20c4 8388 Same as VirtualChannel.10.Main.PVVirtualChannel.10.Alarm1.Inactive 1 = alarm source safe and ack’d (if necessary) bool 20ce 8398 Not applicableVirtualChannel.10.Alarm1.Inhibit 1 = alarm inhibited bool 20d1 8401 Not applicableVirtualChannel.10.Alarm1.Latch As VirtualChannel1.Alarm1.Latch uint8 20c1 8385 Not applicableVirtualChannel.10.Alarm1.NotAcknowledged 1 = alarm has not been acknowledged bool 20cf 8399 Not applicableVirtualChannel.10.Alarm1.Reference Deviation alarm ‘Reference’ value float32 20c6 8390 Same as VirtualChannel.10.Main.PVVirtualChannel.10.Alarm1.Status As VirtualChannel1.Alarm1.Status uint8 0146 326 Not applicableVirtualChannel.10.Alarm1.Threshold Alarm trigger threshold float32 20c3 8387 Same as VirtualChannel.10.Main.PVVirtualChannel.10.Alarm1.Type As VirtualChannel1.Alarm1.Type uint8 20c0 8384 Not applicableVirtualChannel.10.Alarm2.Acknowledge 1 = acknowledge alarm bool 01d3 467 Not applicableVirtualChannel.10.Alarm2.Acknowledgement 1 = alarm acknowledged bool 20f0 8432 Not applicableVirtualChannel.10.Alarm2.Active 1 = alarm source active, or safe but not ack’d bool 20eb 8427 Not applicableVirtualChannel.10.Alarm2.Amount Rate-of-change alarm ‘Amount’ float32 20e8 8424 Same as VirtualChannel.10.Main.PVVirtualChannel.10.Alarm2.AverageTime Rate-of-change alarm ‘Average time’ time_t 20ea 8426 Set by Network.Modbus.TimeFormatVirtualChannel.10.Alarm2.Block 0 = Blocking alarms off; 1 = Blocking alarms on uint8 20e2 8418 Not applicableVirtualChannel.10.Alarm2.ChangeTime Rate-of-change alarm ‘Change Time’ uint8 20e9 8425 Not applicableVirtualChannel.10.Alarm2.Deviation Deviation alarm ‘Deviation Value’ float32 20e7 8423 Same as VirtualChannel.10.Main.PVVirtualChannel.10.Alarm2.Dwell Alarm dwell time time_t 20e5 8421 Set by Network.Modbus.TimeFormatVirtualChannel.10.Alarm2.Hysteresis Alarm hysteresis value float32 20e4 8420 Same as VirtualChannel.10.Main.PVVirtualChannel.10.Alarm2.Inactive 1 = alarm source safe and ack’d (if necessary) bool 20ee 8430 Not applicableVirtualChannel.10.Alarm2.Inhibit 1 = alarm inhibited bool 20f1 8433 Not applicableVirtualChannel.10.Alarm2.Latch As VirtualChannel1.Alarm1.Latch uint8 20e1 8417 Not applicableVirtualChannel.10.Alarm2.NotAcknowledged 1 = alarm has not been acknowledged bool 20ef 8431 Not applicableVirtualChannel.10.Alarm2.Reference Deviation alarm ‘Reference’ value float32 20e6 8422 Same as VirtualChannel.10.Main.PVVirtualChannel.10.Alarm2.Status As VirtualChannel1.Alarm1.Status uint8 0147 327 Not applicableVirtualChannel.10.Alarm2.Threshold Alarm trigger threshold float32 20e3 8419 Same as VirtualChannel.10.Main.PVVirtualChannel.10.Alarm2.Type As VirtualChannel1.Alarm1.Type uint8 20e0 8416 Not applicableVirtualChannel.10.Main.Descriptor Virtual Channel descriptor string_t 4bf3 19443 Not applicableVirtualChannel.10.Main.Disable 1 = Virtual channel disabled bool 20a3 8355 Not applicableVirtualChannel.10.Main.HighCutOff The highest input value that will be totalised/counted float32 2085 8325 Set by VirtualChannel.10.Main.ResolutionVirtualChannel.10.Main.Input1 Input 1 value float32 2087 8327 Set by VirtualChannel.10.Main.ResolutionVirtualChannel.10.Main.Input2 Input 2 value float32 2088 8328 Set by VirtualChannel.10.Main.ResolutionVirtualChannel.10.Main.LowCutOff The lowest input value that will be totalised/counted float32 2084 8324 Set by VirtualChannel.10.Main.ResolutionVirtualChannel.10.Main.ModbusInput Modbus input value float32 2086 8326 Set by VirtualChannel.10.Main.ResolutionVirtualChannel.10.Main.Operation As VirtualChannel1.Main.Operation uint8 2081 8321 Not applicableVirtualChannel.10.Main.Period Averaging period int32 208a 8330 Not applicableVirtualChannel.10.Main.Preset Initiate preset. 0 = No; 1 = Yes bool 208c 8332 Not applicableVirtualChannel.10.Main.PresetValue The Preset value float32 208d 8333 Set by VirtualChannel.10.Main.ResolutionVirtualChannel.10.Main.PV The virtual channel output value float32 0144 324 Set by VirtualChannel.10.Main.ResolutionVirtualChannel.10.Main.Reset Initiate reset. 0 = No; 1 = Yes bool 208b 8331 Not applicableVirtualChannel.10.Main.Resolution Number of decimal places (0 to 6) uint8 2082 8322 Not applicableVirtualChannel.10.Main.Rollover A pulse signal to indicate PV (output) has just rolled over bool 2091 8337 Not applicableVirtualChannel.10.Main.RolloverValue Rollover value float32 2092 8338 Set by VirtualChannel.10.Main.ResolutionVirtualChannel.10.Main.Status As VirtualChannel1.Main.Status uint8 0145 325 Not applicableVirtualChannel.10.Main.TimeRemaining Time remaining before the calculation is made time_t 2089 8329 Set by Network.Modbus.TimeFormatVirtualChannel.10.Main.Trigger Increment/decrement counter. 0 = No; 1 = Yes bool 208e 8334 Not applicableVirtualChannel.10.Main.Type As VirtualChannel1.Main.Type uint8 2080 8320 Not applicableVirtualChannel.10.Main.Units Units descriptor string_t 4c08 19464 Not applicableHA030554Issue 7 Nov 12Page 246

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!