nanodac RECORDER/CONTROLLER: USER GUIDE4.16.2 Configuration (Cont.)GAS REFERENCES PARAMETERSCO LocalReference value for the carbon monoxide (CO) concentration in the atmosphere.CO Remote Remote reference value for the carbon monoxide concentration in the atmosphere. allowsthe value to be read remotely.CO Remote En ‘Yes’ allows remote CO measurement. ‘No’ uses the internal value.CO in Use The CO gas measurement value currently being used.H2 LocalReference value for the hydrogen (H) concentration in the atmosphere.H2 Remote Remote reference value for the hydrogen concentration in the atmosphere. allows thevalue to be read remotely.H2 Remote En ‘Yes’ allows remote H measurement. ‘No’ uses the internal value.H2 In UseThe H gas measurement value currently being used.CLEAN PARAMETERSClean FrequencyClean TimeMin Rcov TimeMax Rcov timeClean ValveClean ProbeTime to CleanClean EnableClean Max TempClean AbortClean Rcov TimeLast CleanClean Msg ResetProbe FaultCant CleanClean AbortClean TempAllows the interval between probe cleaning cycles to be entered in hours and minutes.Allows Probe clean time to be entered in hours and minutes.The minimum recovery time after purging in hours and minutes.The maximum recovery time after purging in hours and minutes.Read only. Enable the Clean valve.Initiate probe cleaningRead only. The time remaining, in hours and minutes until the next cleaning cycle isdue.Enable probe cleaningMaximum temperature for cleaning. If the temperature exceeds this value, cleaning isaborted.Abort probe cleaningThe time taken for the probe to recover to 95% of its original value after the last clean.If the last clean did not recover within the Max Rcov time, this value is set to 0.The mV output from the probe after the last clean.‘Yes’ clears cleaning related alarms‘Yes’ means that the probe failed to recover to 95% of its original output, following aclean,Conditions exist which prevent a clean cycle starting. Can be cleared using ‘Clean MsgReset’.A clean cycle was aborted. Can be cleared using ‘Clean Msg Reset’.A clean cycle was aborted because the temperature was too high. Can be cleared using‘Clean Msg Reset’.HA030554Issue 7 Nov 12Page 153

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!