User Guide - Eurotherm Ltda
User Guide - Eurotherm Ltda
User Guide - Eurotherm Ltda
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
nanodac RECORDER/CONTROLLER: USER GUIDEParameter path Description Type Hex Dec ResolutionSegment.15.Ch2TSP Channel 2 target set-point float32 3d63 15715 Same as Programmer.SetUp.Ch2PVInputSegment.15.Ch2<strong>User</strong>Val Channel 2 user value float32 3d79 15737 Same as Programmer.SetUp.ResetCh2<strong>User</strong>ValSegment.15.Ch2Wait Channel 2 Wait uint8 3d6f 15727 Not applicableSegment.15.Ch2WaitVal Channel 2 wait value float32 3d71 15729 Same as Programmer.SetUp.PVWait2Segment.15.Cycles Cycles int16 3d73 15731 Not applicableSegment.15.Duration Duration time_t 3d61 15713 Set by Network.Modbus.TimeFormatSegment.15.EndType End type uint8 3d68 15720 Not applicableSegment.15.Event1 Event 1 bool 3d7a 15738 Not applicableSegment.15.Event2 Event 2 bool 3d7b 15739 Not applicableSegment.15.Event3 Event 3 bool 3d7c 15740 Not applicableSegment.15.Event4 Event 4 bool 3d7d 15741 Not applicableSegment.15.Event5 Event 5 bool 3d7e 15742 Not applicableSegment.15.Event6 Event 6 bool 3d7f 15743 Not applicableSegment.15.Event7 Event 7 bool 3d80 15744 Not applicableSegment.15.Event8 Event 8 bool 3d81 15745 Not applicableSegment.15.GoBackTo Go back to uint8 3d72 15730 Not applicableSegment.15.SegmentName Segment name string_t 6bf6 27638 Not applicableSegment.15.Type Type uint8 3d60 15712 Not applicableSegment.15.WaitFor Wait for uint8 3d6d 15725 Not applicableSegment.16.Ch1Holdback Channel 1 holdback type uint8 3d99 15769 Not applicableSegment.16.Ch1HoldbackVal Channel 1 holdback value float32 3d9b 15771 Same as Programmer.SetUp.Ch1PVInputSegment.16.Ch1PVEvent Channel 1 PV event uint8 3da4 15780 Not applicableSegment.16.Ch1PVEventUse Channel 1 PV event use bool 3db2 15794 Not applicableSegment.16.Ch1PVEventVal Channel 1 PV event value float32 3da6 15782 Same as Programmer.SetUp.Ch1PVInputSegment.16.Ch1Rate Channel 1 rate float32 3d96 15766 Set by Programmer.SetUp.RateResolutionSegment.16.Ch1Time Channel 1 time time_t 3d94 15764 Set by Network.Modbus.TimeFormatSegment.16.Ch1TSP Channel 1 target set-point float32 3d92 15762 Same as Programmer.SetUp.Ch1PVInputSegment.16.Ch1<strong>User</strong>Val Channel 1 user value float32 3da8 15784 Same as Programmer.SetUp.ResetCh1<strong>User</strong>ValSegment.16.Ch1Wait Channel 1 Wait For parameteruint8 3d9e 15774 Not applicableSegment.16.Ch1WaitVal Channel 1 wait value values and settings float32 3da0 15776 Same as Programmer.SetUp.PVWait1Segment.16.Ch2Holdback Channel 2 holdback type uint8 3d9a 15770 Not applicableSegment.16.Ch2HoldbackVal Channel 2 holdback value(enumerations),float32 3d9c 15772 Same as Programmer.SetUp.Ch2PVInputSegment.16.Ch2PVEvent Channel 2 PV event see Segment 1uint8 3da5 15781 Not applicableSegment.16.Ch2PVEventUse Channel 2 PV event use bool 3db3 15795 Not applicableSegment.16.Ch2PVEventVal Channel 2 PV event value float32 3da7 15783 Same as Programmer.SetUp.Ch2PVInputSegment.16.Ch2Rate Channel 2 rate float32 3d97 15767 Set by Programmer.SetUp.RateResolutionSegment.16.Ch2Time Channel 2 time time_t 3d95 15765 Set by Network.Modbus.TimeFormatSegment.16.Ch2TSP Channel 2 target set-point float32 3d93 15763 Same as Programmer.SetUp.Ch2PVInputSegment.16.Ch2<strong>User</strong>Val Channel 2 user value float32 3da9 15785 Same as Programmer.SetUp.ResetCh2<strong>User</strong>ValSegment.16.Ch2Wait Channel 2 Wait uint8 3d9f 15775 Not applicableSegment.16.Ch2WaitVal Channel 2 wait value float32 3da1 15777 Same as Programmer.SetUp.PVWait2Segment.16.Cycles Cycles int16 3da3 15779 Not applicableSegment.16.Duration Duration time_t 3d91 15761 Set by Network.Modbus.TimeFormatSegment.16.EndType End type uint8 3d98 15768 Not applicableSegment.16.Event1 Event 1 bool 3daa 15786 Not applicableSegment.16.Event2 Event 2 bool 3dab 15787 Not applicableSegment.16.Event3 Event 3 bool 3dac 15788 Not applicableSegment.16.Event4 Event 4 bool 3dad 15789 Not applicableSegment.16.Event5 Event 5 bool 3dae 15790 Not applicableSegment.16.Event6 Event 6 bool 3daf 15791 Not applicableSegment.16.Event7 Event 7 bool 3db0 15792 Not applicableSegment.16.Event8 Event 8 bool 3db1 15793 Not applicableSegment.16.GoBackTo Go back to uint8 3da2 15778 Not applicableSegment.16.SegmentName Segment name string_t 6c0b 27659 Not applicableSegment.16.Type Type uint8 3d90 15760 Not applicableSegment.16.WaitFor Wait for uint8 3d9d 15773 Not applicableSegment.17.Ch1Holdback Channel 1 holdback type uint8 3dc9 15817 Not applicableSegment.17.Ch1HoldbackVal Channel 1 holdback value float32 3dcb 15819 Same as Programmer.SetUp.Ch1PVInputSegment.17.Ch1PVEvent Channel 1 PV event uint8 3dd4 15828 Not applicableSegment.17.Ch1PVEventUse Channel 1 PV event use bool 3de2 15842 Not applicableSegment.17.Ch1PVEventVal Channel 1 PV event value float32 3dd6 15830 Same as Programmer.SetUp.Ch1PVInputSegment.17.Ch1Rate Channel 1 rate float32 3dc6 15814 Set by Programmer.SetUp.RateResolutionSegment.17.Ch1Time Channel 1 time time_t 3dc4 15812 Set by Network.Modbus.TimeFormatSegment.17.Ch1TSP Channel 1 target set-point float32 3dc2 15810 Same as Programmer.SetUp.Ch1PVInputSegment.17.Ch1<strong>User</strong>Val Channel 1 user value float32 3dd8 15832 Same as Programmer.SetUp.ResetCh1<strong>User</strong>ValSegment.17.Ch1Wait Channel 1 Wait uint8 3dce 15822 Not applicableSegment.17.Ch1WaitVal Channel 1 wait value float32 3dd0 15824 Same as Programmer.SetUp.PVWait1Segment.17.Ch2Holdback Channel 2 holdback type uint8 3dca 15818 Not applicableSegment.17.Ch2HoldbackVal Channel 2 holdback value float32 3dcc 15820 Same as Programmer.SetUp.Ch2PVInputSegment.17.Ch2PVEvent Channel 2 PV event uint8 3dd5 15829 Not applicableSegment.17.Ch2PVEventUse Channel 2 PV event use bool 3de3 15843 Not applicableSegment.17.Ch2PVEventVal Channel 2 PV event value float32 3dd7 15831 Same as Programmer.SetUp.Ch2PVInputSegment.17.Ch2Rate Channel 2 rate float32 3dc7 15815 Set by Programmer.SetUp.RateResolutionSegment.17.Ch2Time Channel 2 time time_t 3dc5 15813 Set by Network.Modbus.TimeFormatSegment.17.Ch2TSP Channel 2 target set-point float32 3dc3 15811 Same as Programmer.SetUp.Ch2PVInputSegment.17.Ch2<strong>User</strong>Val Channel 2 user value float32 3dd9 15833 Same as Programmer.SetUp.ResetCh2<strong>User</strong>ValSegment.17.Ch2Wait Channel 2 Wait uint8 3dcf 15823 Not applicableSegment.17.Ch2WaitVal Channel 2 wait value float32 3dd1 15825 Same as Programmer.SetUp.PVWait2Segment.17.Cycles Cycles int16 3dd3 15827 Not applicableHA030554Issue 7 Nov 12Page 228