nanodac RECORDER/CONTROLLER: USER GUIDE4.8.3 Programmer Set Up Menu (Cont.)ResetRun ResetRun HoldWait DigitalWait Analog 1Wait Analog 2AdvanceOperationStatusAmendedFile Error StatusProgram NumThe input that causes the programmer to place the current program in Reset mode.Dual functionality input, that causes the programmer to place the current program inRun or Reset mode.Dual functionality input, that causes the programmer to place the current program inRun or Hold mode.The Boolean input that is used in Wait segments.The analogue input associated with channel 1 that is used in wait segments.The analogue input associated with channel 2 that is used in wait segments. Appearsonly if ‘Channels’ = ‘2’The input to advance the current segmentProgram file operation selection parameter. See ‘Program editing’ (Section 3.4.9) forfurther detailsStatus indication of the selected file operation.See ‘Program editing’ (Section 3.4.9) forfurther detailsIndicates whether the current program has been amended since being loaded (Commsonly)File operation error status (Busy, OK, Load Open File Error, Store Open File Error, DeleteFile Fail, Copy File Fail, Invalid Format, Invalid Device, Invalid Version, Invalid NumChannels, Parameter Write Fail, Store Operation Did Not Complete, Load OperationDid Not Complete, Delete Operation Did Not Complete, Copy Operation Did NotComplete, Invalid Filename, Unspecified Error). Available only over Comms as the erroris displayed on the display screen.'Parameter Write Fail' indicates that one or more program/segment parameters failedto be written to during a 'Load' operation. This is generally caused by a program thatcontains features (i.e. Holdback, <strong>User</strong> Values, PV Events) which are disabled in the instrument'sProgrammer block, or the program contains more Event Outputs than configuredin the instrument's Programmer block.A program name may be prefixed by a program number from 1 to 99. This is necessaryif a program is to be loaded either using a BCD switch or via a single comms transaction.The parameter shows the last program to be loaded via the program number. See alsoSection 3.4.9. ‘Program Load Via a Program Number’.Page 130HA030554Issue 7 Nov 12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!