nanodac RECORDER/CONTROLLER: USER GUIDE4.7.7 Advanced Loop Slave SP menuAdvanced Loop.Slave.SPRange HighRange LowSP High LimitSP Low LimitLocal SPTrim Range HighTrim Range LowTrim High LimitTrim Low LimitRemote FFRemote FF EnableRemote FF HighRemote FF LowManual Track1372.0 V-200 V1372.0-2001372.0100.0-100.0100.0 V-100 V0.0No1372.0-200OffFigure 4.7.7a Advanced Loop Slave Setpint menuRange High/LowSP High LimitSP Low LimitLocal SPTrim Range HighTrim Range LowTrim High LimitTrim Low LimitRemote FFRemote FF EnableRemote FF HighRemote FF LowFF SelectManual TrackRange limits. Valid entries from 99999 to -99999. Range limits set absolute maxima andminima for control loop setpoints. If the proportional band is configured as a % span,the span is derived from the range limits.Maximum setpoint limit for the local setpoint. Valid entries are in the range ‘Range Hi’and ‘SP Low Limit’Minimum setpoint limit for the local setpoint. Valid entries are in the range ‘Range Lo’and ‘SP High Limit’The Slave local setpointTrim Range upper limit. Appears only if ‘Cascade type’ has been set to ‘Trim’ in the Setupmenu.Trim Range upper limit. Appears only if ‘Cascade type’ has been set to ‘Trim’ in the Setupmenu.Maximum value for Trim High value. Appears only if ‘Cascade type’ has been set to‘Trim’ in the Setup menu.Minimum value for Trim Low value. Appears only if ‘Cascade type’ has been set to ‘Trim’in the Setup menu.The current remote feedforward valueEnables or disables the use of a remote Feedforward signal. Appears only if ‘Cascadetype’ has been set to ‘Full Scale’ in the Setup menu.High limit for the remote feedforward signal value. Appears only if ‘Cascade type’ hasbeen set to ‘Full Scale’ in the Setup menu.Low limit for the remote feedforward signal value. Appears only if ‘Cascade type’ hasbeen set to ‘Full Scale’ in the Setup menu.Allows the user to select the source of the feedforward signal from ‘master PV’, Masterworking setpoint’ or Remote FF’. Appears only if ‘Cascade type’ has been set to ‘Trim’in the Setup menu.‘On’ enables manual tracking to allow the local SP to follow the value of the current PVto allow bumpless transfer when switching to Auto. See section B2.5.5 for more details.‘Off’ disables manual tracking.Page 118HA030554Issue 7 Nov 12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!