nanodac RECORDER/CONTROLLER: USER GUIDEParameter path Description Type Hex Dec ResolutionLoop.1.OP.OutputHighLimit Output High Limit float32 166d 5741 1dpLoop.1.OP.OutputLowLimit Output Low Limit float32 166e 5742 Same as Loop.1.OP.OutputHighLimitLoop.1.OP.PotBreakMode Potentiometer Break Mode uint8 167c 5756 Not applicable(0 = Raise; 1 = Lower; 2 = Rest: 3 = Model)Loop.1.OP.Rate Output Rate Limit Value (0 = Off) float32 1670 5744 1dpLoop.1.OP.RateDisable Output Rate Limit Disable (1 = Disabled) bool 1671 5745 Not applicableLoop.1.OP.RemOPH Remote Output High Limit float32 168c 5772 Same as Loop.1.Main.ActiveOutLoop.1.OP.RemOPL Remote Output Low Limit float32 168b 5771 Same as Loop.1.Main.ActiveOutLoop.1.OP.SafeOutVal Safe Output Value float32 167e 5758 Same as Loop.1.OP.OutputHighLimitLoop.1.OP.SbrkOP The output power in sensor break float32 168e 5774 Same as Loop.1.OP.OutputHighLimitLoop.1.OP.SensorBreakMode Sensor Break Mode (0 = SbrkOP; 1 = Hold) uint8 167d 5757 Not applicableLoop.1.OP.TrackEnable Enable Output Tracking (0 = Disabled; 1 = Enabled) uint8 168a 5770 Not applicableLoop.1.OP.TrackOutVal Output Track Value float32 1689 5769 0dpLoop.1.PID.ActiveSet Current PID Set uint8 1638 5688 Not applicableLoop.1.PID.Boundary1-2 Threshold for swapping between set 1 and set 2 float32 1639 5689 0dpLoop.1.PID.Boundary2-3 Threshold for swapping between set 2 and set 3 float32 163a 5690 0dpLoop.1.PID.CutbackHigh Cutback high value for PID set 1 (0 = Auto) float32 163f 5695 1dpLoop.1.PID.CutbackHigh2 Cutback high value for PID set 2 (0 = Auto) float32 1647 5703 1dpLoop.1.PID.CutbackHigh3 Cutback high value for PID set 3 (0 = Auto) float32 164f 5711 1dpLoop.1.PID.CutbackLow Cutback low value for PID set 1 (0 = Auto) float32 1640 5696 1dpLoop.1.PID.CutbackLow2 Cutback low value for PID set 2 (0 = Auto) float32 1648 5704 1dpLoop.1.PID.CutbackLow3 Cutback low value for PID set 3 (0 = Auto) float32 1650 5712 1dpLoop.1.PID.DerivativeTime Derivative time for PID set 1 float32 163d 5693 0dpLoop.1.PID.DerivativeTime2 Derivative time for PID set 2 float32 1645 5701 0dpLoop.1.PID.DerivativeTime3 Derivative time for PID set 3 float32 164d 5709 0dpLoop.1.PID.IntegralTime Integral time for PID set 1 float32 163c 5692 0dpLoop.1.PID.IntegralTime2 Integral time for PID set 2 float32 1644 5700 0dpLoop.1.PID.IntegralTime3 Integral time for PID set 3 float32 164c 5708 0dpLoop.1.PID.LoopBreakTime Loop break time for PID set 1 float32 1642 5698 0dpLoop.1.PID.LoopBreakTime2 Loop break time for PID set 2 float32 164a 5706 0dpLoop.1.PID.LoopBreakTime3 Loop break time for PID set 3 float32 1652 5714 0dpLoop.1.PID.ManualReset Manual reset value for PID set 1 float32 1641 5697 1dpLoop.1.PID.ManualReset2 Manual reset value for PID set 2 float32 1649 5705 1dpLoop.1.PID.ManualReset3 Manual reset value for PID set 3 float32 1651 5713 1dpLoop.1.PID.NumSets Number of PID Sets to be used (max = 3) uint8 1636 5686 Not applicableLoop.1.PID.OutputHi Gain scheduled output high limit for PID set 1 float32 1653 5715 1dpLoop.1.PID.OutputHi2 Gain scheduled output high limit for PID set 2 float32 1655 5717 1dpLoop.1.PID.OutputHi3 Gain scheduled output high limit for PID set 3 float32 1657 5719 1dpLoop.1.PID.OutputLo Gain scheduled output low limit for PID set 1 float32 1654 5716 1dpLoop.1.PID.OutputLo2 Gain scheduled output low limit for PID set 2 float32 1656 5718 1dpLoop.1.PID.OutputLo3 Gain scheduled output low limit for PID set 3 float32 1658 5720 1dpLoop.1.PID.ProportionalBand Proportional band value for PID set 1 float32 163b 5691 1dpLoop.1.PID.ProportionalBand2 Proportional band value for PID set 2 float32 1643 5699 1dpLoop.1.PID.ProportionalBand3 Proportional band value for PID set 3 float32 164b 5707 1dpLoop.1.PID.RelCh2Gain Channel 2 relative cool gain value for PID set 1 float32 163e 5694 1dpLoop.1.PID.RelCh2Gain2 Channel 2 relative cool gain value for PID set 2 float32 1646 5702 1dpLoop.1.PID.RelCh2Gain3 Channel 2 relative cool gain value for PID set 3 float32 164e 5710 1dpLoop.1.PID.SchedulerRemoteInput Scheduler Remote Input float32 1637 5687 0dpLoop.1.PID.SchedulerType Scheduler Type uint8 1635 5685 Not applicable0 = Off 1 = Set 2 = SP 3 = PV4 = Error 5 = OP 6 = RemLoop.1.Setup.AutoManAccess Edit access to ‘Auto Man’ in Loop display page uint8 16a8 5800 Not applicable0 = Read/Write (R/W) all modes1 = Editable in all modes except ‘Logged out’2 = Editable only at Engineer and Supervisor levelsLoop.1.Setup.CH1ControlTypeHeat/Ch1 Control Type0 =Off; 1 = On Off; 2 = PID; 3 = VPU; 4 = VPB uint8 1601 5633 Not applicableLoop.1.Setup.CH2ControlType Channel 2 control type (As channel 1, above) uint8 1602 5634 Not applicableLoop.1.Setup.ControlAction Control Action (0 = Reverse; 1 = Direct) uint8 1603 5635 Not applicableLoop.1.Setup.DerivativeType Derivative Type (0 = PV; 1 = Error) uint8 1605 5637 Not applicableLoop.1.Setup.ManOutputAccess Manual output access uint8 16a9 5801 Not applicableLoop.1.Setup.LoopName Loop Name string_t 5d00 23808 Not applicableLoop.1.Setup.LoopType Loop Type (0 = Single; 1 = Cascade; 2 = Override; 3 = Ratio) uint8 1600 5632 Not applicableLoop.1.Setup.PBUnits Proportional Band Units uint8 1604 5636 Not applicableLoop.1.Setup.SPAccess Edit access to ‘SP’ in Loop display page uint8 16a7 5799Not applicable0 = Read/Write (R/W) all modes1 = Editable in all modes except ‘Logged out’2 = Editable only at Engineer and Supervisor levelsLoop.1.SP.AltSP Alternative Setpoint float32 1660 5728 Same as Loop.1.Main.PVLoop.1.SP.AltSPSelect Alternative Setpoint Enable (0 = disable; 1 = enable) uint8 1661 5729 Not applicableLoop.1.SP.ManualTrack Manual Track Enable (0 = disable; 1 = enable) uint8 1667 5735 Not applicableLoop.1.SP.RangeHigh Setpoint Range High Limit float32 1659 5721 Same as Loop.1.Main.PVLoop.1.SP.RangeLow Setpoint Range Low Limit float32 165a 5722 Same as Loop.1.Main.PVLoop.1.SP.Rate Setpoint Rate Limit Value (0 = Rate limit off) float32 1662 5730 Same as Loop.1.Main.PVLoop.1.SP.RateDisable Setpoint Rate Limit Disable (0 = No; 1 = Yes) bool 1663 5731 Not applicableLoop.1.SP.RateDone Setpoint Rate Limit Complete (0 = No; 1 = Yes) bool 020a 522 Not applicableLoop.1.SP.ServoToPV Servo to PV Enable (0 = No; 1 = Yes) bool 166c 5740 Not applicableLoop.1.SP.SP1 Setpoint 1 float32 165c 5724 Same as Loop.1.Main.PVLoop.1.SP.SP2 Setpoint 2 float32 165d 5725 Same as Loop.1.Main.PVLoop.1.SP.SPHighLimit Setpoint High Limit float32 165e 5726 Same as Loop.1.Main.PVHA030554Issue 7 Nov 12Page 200

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!