11.07.2015 Views

mixed use regulations and development standards - Garden Grove

mixed use regulations and development standards - Garden Grove

mixed use regulations and development standards - Garden Grove

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Garden</strong> <strong>Grove</strong> Mixed Use ZonesZoning Ordinance AmendmentSECTION 9.18.090.080: Adaptive Re<strong>use</strong> Zone (AR) Development St<strong>and</strong>ards.In addition to the other applicable requirements of this Chapter, the provisions ofthis subsection 9.18.090.080 apply to proposed <strong>development</strong> in the AR zone. Table9.18-7 (Development St<strong>and</strong>ards for the Adaptive Re<strong>use</strong> Zone) establishes the<strong>development</strong> st<strong>and</strong>ards applicable to all <strong>development</strong> in the AR zone.TABLE 9.18-7Development St<strong>and</strong>ards for the Adaptive Re<strong>use</strong> ZoneDEVELOPMENT STANDARDSMinimum Lot SizeMinimum AreaMinimum WidthMinimum Width (Corner Lot)Maximum Density/IntensityMaximum Commercial Floor AreaRatio (FAR)Maximum Residential Density(units/acre)SetbacksFrontSideCorner SideRearMaximum HeightLot CoverageMinimum Lot CoverageMaximum Lot CoverageADAPTIVE REUSE ZONE (AR)Minimum area <strong>and</strong> width for new lots. When a lot hasless than the minimum required area or width as set forthin the <strong>development</strong> st<strong>and</strong>ards for the zone in which it islocated <strong>and</strong> was of record on November 12, 1960, the lotshall be deemed to have complied with the currentminimum required lot area or width.15,000 sf75 ft75 ft0.532 units/acreAll residential units shall be work-live units, per Section9.18.020.070.Minimum setbacks required. See Section 9.18.100 forsetback measurement, allowed encroachments <strong>and</strong>projections into setbacks, <strong>and</strong> exceptions tosetbacks.Minimum 15 ftNone requiredMinimum 10 ftNone required unless abutting a residentially zoned lot.minimum 10 ft when abutting a residentially zoned lot. SeeSection 9.18.100.Maximum building height shall not exceed heightlimit in feet or stories. See also Section 9.18.100 forrear <strong>and</strong> side yard encroachment plane requirementswhich may restrict heights adjacent to a residentiallyzoned lot.50 ft or 4 stories, whichever is lessNot applicableNot applicableSection 9.18.090: Development St<strong>and</strong>ards Specific to Individual Mixed Use Zones 88

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!