11.07.2015 Views

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Setting parameters04/07 AWB8230-1541GBJog modeJogging is used, for example, to set up a machine in manual mode.To do this, a digital input (1 to 5) must be activated with the JOG<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mand (=06) under PNU C001 to C005. With a Start signal atthe FWD or REV input, a relatively low frequency withoutacceleration ramp is applied to the motor. This jog frequency is setwith PNU A038. Do not set the frequency too high, as it is applieddirectly to the motor without acceleration ramp. Excessive jogfrequencies can cause a fault. We re<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mend a frequency below5Hz.Use the START and STOP keys to start and stop the motorrespectively.hJog mode is started only through the active JOG input, notthrough the keypad.JOG3FWD1P24hhOperation in jog mode is not possible when the joggingfrequency set under PNU A038 is less than the startfrequency set under PNU b082 (a section “Increasedstarting frequency”, page 69).Jog mode can be activated only when the frequencyinverter is in the Stop state.Figure 100:JOGDigital input 1 configured as FWD (start/stopclockwise operation) and 3 as JOG (jog mode).By default (PNU A002 = 01) the position of microswitch TM/PRGhas no function.The value of PNU AA039 determines how the motor is slowed.h Attention!Make sure that the motor has stopped before using jogmode.The jogging frequency can be read off with an optional keypad.X To do this, enter the value 02 in PNU A002.X Set microswitch TM/PRG to its PRG position.X Activate the digital input configured as JOG.FWD/REVn MaFigure 101: Function chart for JOG modeNM: Motor speeda Depending on the value of PNU A03900: Coasting01: Deceleration ramp02: DC brakingaPNU Designation RUN b031= 10Value Function DSA002A038A039Start signalsourceselectionJog mode Jogmodereference valueJog modeMotor stopmethod– – 01 Digital input (FWD/REV) 0102 LCD keypad: START and STOP key.03 Modbus: Activates a COIL for RUN/STOP and a COIL for FWD/REV.j j 0…9.99 Hz The frequency to be applied to the motor in jog mode. 1.00– j 00 Free coasting (FRS) 0001 Deceleration ramp02 DC braking96

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!