11.07.2015 Views

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

04/07 AWB8230-1541GB Parameter list for userdefinablesettingsPNU Name RUN b031= 10Designation Value range DS Page UsersettingC091 Debug j j Debug mode, view additionalparametersC101C102C141C142C143UV-MotorPotiModeResetStopModeLogiclnALogicInBLogicModeC144 t-onDigiOut11C145 t-offDigiOut11– j Motor potentiometer –reference value for motorpotentiometer after powersupply interruption– j Reset function (RST) – responseto a Reset signal00: Do not show parameter 00 14201: Show parameter00: Clear last value and use default forPNU F00101: Use saved motor potentiometer valueset with UP/DWN function throughdigital inputs.00: On a rising edge the fault signal is resetand the motor is stopped.01: On a falling edge the fault signal isreset and the motor is stopped.02: On a rising edge the fault message isreset.00 9500 183– – Logic function – select input A 00: RUN: In operation 00 12601: FA1: <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> reference value reached02: FA2: <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> signal – outputfrequency exceeds value in PNU C042(during acceleration ramp) orPNU C043 (during deceleration ramp).03: OL: Overload warning – motor currentexceeds value in PNU C041.04: OD, PID con<strong>tr</strong>ol: Reference/actual valuedifference exceeds signalling thresholdset with PNU C044.05: AL: Fault – fault/alarm signal06: Dc: Warning – reference value at inputO (0 to +10 V) lower than value inPNU b082 or current signal at input OIbelow 4 mA.07: FBV: PID con<strong>tr</strong>ol – actual valuemonitoring (PV) signal on breach oflimit values PNU C052/C053.08: NDc: Fault/warning dependent onPNU C077 – <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>munication watchdogtimer has expired: <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>munications arefaulty.10: ODc: Fault/warning: Communicationoverload or interrupted (with optionalDE51-NET-CAN, DE51-NET-DP).– – Logic function – select input B Values a PNU C141 01 126– – Logic function – select link[LOG]– j Digital output 11 – decelerationtime (On)– j Digital output 11 – decelerationtime (Off)00: [LOG] = A AND B 00 12601: [LOG] = A OR B02: [LOG] = A XOR B0…100 s 0.0 1080…100 s 0.0 108243

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!