11.07.2015 Views

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

04/07 AWB8230-1541GB KeypadQuick parameter selectionX With the PRG key, change to parameterization mode (4-digitparameter indication, for example d001).X Press both arrow keys Í and Ú at the same time and releasethem again.The quick selection mode is now selected. The first digit of thedigital display flashes.X To select the required parameter range (A, b, C, d, F orH), press one of the arrow keys (Í or Ú). The correspondingletter appears in the main menu.Figure 59:7-segment display1 2 3 4X To change to the second, third and fourth digit of the display,press the Enter key each time. The active digit flashes in eachcase.X To change the value of the active digit (0 to 9), use thearrow keys (Í or Ú).X When you press Enter again after the fourth digit, the enteredparameter is called up.If the number you have entered does not exist, the last valid PNUis selected again when you press the Enter key.X To go back to the last valid PNU from the first digit, press thePRG key.Setting the display parametersBy default, the digital display indicates the output frequency (HzLED is lit). The following section lists the other operational datathat can be displayed.hhYou can call up the parameters of the display menu (d…)in both RUN- and STOP mode.The selected display parameter (d…, PNU) isautomatically saved in the event of a mains power failureor disconnection and is displayed again when power isrestored.If the PNU value you have selected is to be shown againthe next time the device is switched on, press the ENTERkey to save it before switching off.X Press the PRG- key. The display indicates PNU d001 (outputfrequency).X To change to the next display parameter (PNU d002 = motorcurrent) press the arrow key Í.When you have selected a display parameter (d…), press the PRGkey, to display that parameter’s value. Parameter and selectedindication are not saved. To save the display parameter (d...) (notthe selected indication), press first the ENTER key and then PRG.To save the display form, press first the PRG key and then ENTER.Display parameters d080 to d083 show the identified faults. Foreach fault signal a fault register en<strong>tr</strong>y containing the operationaldata at the time of the fault (current, voltage, frequency, etc.) iscreated. You can call up the fault register with the PRG key and theassociated operational data with the arrow keys (a section“Fault signal register”, page 182).57

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!