Using the DF5104/07 AWB8230-1541GBTable 17:Indication parameterPNU Designation Functiond001 Output frequency display Displays the output frequency in Hertz (Hz). The Hz LED is lit.d002 Output current display Displays the output current in amperes (A). The A LED is lit.d003 Direction of rotation display Display:• F for clockwise operation (forward)• r for anticlockwise operation (reverse)•o for stopd004 PID feedback display Indication in % if PID con<strong>tr</strong>ol enabled. The factor is set with PNU A075. Default is 0.00.d005d006d007Indication – status of digitalinputs 1 to 5Indication – status of digitaloutputs 11 and 12, and relay K1Indication – scaled outputfrequencyExample: Digital inputs 1, 3 and 5 are activated. Digital inputs 2 and 4 aredeactivated. Digital inputs 2, 4 and 6 are disabled.6 5 4 3 2 1Example: Digital output 11 and relay output (N/O contact K11-K14) areenabled. Digital output 12 is deactivated.K14 12 11Indication of the product of the factor (PNU b086) and the output frequency.Examples:• Maximum output frequency 50 Hz• Factor PNU b086 = 25• Indication 1500, corresponds with the synchronous speed of a four-pole motor.d013 Indication – output voltage Indication of motor voltage at 50 Hz in volts (V).d016Indication – operation timecounterTotal time in hours in which DF51 is in RUN operation.d017 Indication – mains On time Total time in hour in which DF51 was live (mains, internal DC link) (Power display).d080d081Indication – total number ofoccurred faultsIndication – fault 1 (last faultsignal)Total number of detected fault signals (E…).Indication of last fault signal. The fault register contains the operational data (current, voltage,frequency, etc.) at the time of the fault.d082 Indication – fault 2 Display of fourth from last fault message. The fault register contains the operational data (current,voltage, frequency, etc.) at the time of the fault.d083 Indication – fault 3 Display of third from last fault message. The fault register contains the operational data (current,voltage, frequency, etc.) at the time of the fault.hIf the DF51 frequency inverter is connected to a field bus(CANopen, PROFIBUS-DP) or an external keypad throughthe serial interface, use PNU b89 to call up the displayparameters (section “Displayed value (selection withPNU b089)”, page 147).58

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!