Setting parameters04/07 AWB8230-1541GBInitialization (default settings)You can perform the following initialization actions:• Clearing the fault register.• Restoring the default parameter settings• Activating coun<strong>tr</strong>y-specific settings.hWith the initialization, all parameters are reset to theirfactory default values.X Make sure that PNU b085 is set to the correct coun<strong>tr</strong>y version.h Attention!For DF51-322 and DF51-340 only the value 01 (EU) ispermissible, and for DF51-320 only the value 02 (USA).X In PNU b085 enter the value 01 {02} and confirm your inputwith the ENTER key.hCarry out this initialization step after setting PNU b084and before pressing any keys only when needed.hThe default settings can be recalled only in STOP mode(a PNU b151 = 00, page 138).PRGPOWERPRGX Under PNU b084 enter the corresponding value (00, 01 or 02).X Press the ENTER key to save the value.X On the keypad, press and hold arrow key Ú and the PRG key atthe same time.X While holding the arrow and PRG keys, briefly press the Stopkey.Figure 155:ENTERPOWERInitializing the coun<strong>tr</strong>y-specific default settings forEuropeTo clear the fault register and/or to restore the default settings,proceed as follows:The keypad’s display shows EU (if b085 = 01) or USA (ifb085 = 02).X Now release all keys again.In the display’s left field the individual segments light up insequence. At the same time, the Hz, START, RUN and thepotentiometer LEDs light up. When initialization is <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>pleted, allLEDs go out and the display shows d001 (frequency indication).Initialization is now <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>plete.You can now press the PRG key to return to the frequencyindication (Hz) and ENTER to save this display preference.PNU Designation RUN b031= 10Value Function DSb084 Initializing –functionb085 Initialization,coun<strong>tr</strong>yspecificdefaultsettings1) 02 forDF51-320-…– – 00: TRP: Clear fault register 0001: DATA: Load default settings (DS)02: ALL: Clear fault register and load default settings (DS)– – 00 Japan 0101 Europe{02}1)02 USA140

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!