11.07.2015 Views

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Serial interface (Modbus)04/07 AWB8230-1541GBHoldingregisterFunctioncodeDesignationAccessrightsValue rangeManipulatedvariablehex1052 A052 DC braking – startingfrequencyrw 0…60 Hz 0.1 [Hz]1053 A053 DC braking – waiting time rw 0…5 s 0.1 [s]1054 A054 DC braking – braking torque rw 0…100 % 1 [%]1055 A055 DC braking – brakingduration1056 A056 DC braking – behaviour onactivation of the digitalinput (DB)rw 0…60 s 0.1 [s]rw 00: Timed braking according to value ofPNU A05501: Continuous operation1057 A057 Reserved rw – –1058 A058 Reserved rw – –1059 A059 Reserved rw – –105 A A061 Maximum operatingfrequency105B A062 Minimum operatingfrequencyrw 0…400 Hz 0.1 [Hz]rw 0…400 Hz 0.1 [Hz]105C A063 Reserved rw – –105D A063 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> jump (1) rw 0…400 Hz 0.1105E A064 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> jump (1) – jumpwidthrw 0…10 Hz 0.1 [Hz]105F A065 Reserved rw – –1060 A065 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> jump (2) rw 0…400 Hz 0.11061 A066 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> jump (2) – jumpwidthrw 0…10 Hz 0.1 [Hz]1062 A067 Reserved rw – –1063 A067 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> jump (3) rw 0…400 Hz 0.11064 A068 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> jump (3) – jumpwidthrw 0…10 Hz 0.1 [Hz]1065 A069 Reserved rw – –1066 A069 Reserved rw – –1067 A070 Reserved rw – –1068 A071 PID con<strong>tr</strong>ol rw 00: Off: Disabled –1069 A072 PID con<strong>tr</strong>oller – P-<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponent106 A A073 PID con<strong>tr</strong>oller – I-<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponent106B A074 PID con<strong>tr</strong>oller – D-<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponent01: On: Enabledrw 0.2…5.0 0.1rw 0.00…100 s 0.1 [s]rw 0.00…100 s 0.1 [s]106C A075 PID con<strong>tr</strong>ol, display factor rw 0.01…99.99 0,01106D A076 PID con<strong>tr</strong>oller – actual valuesignal PV inpu<strong>tr</strong>w 00: Analog input OI (4…20 mA) –01: Analog input O (0…10 V)02: Serial interface (Modbus)10: Calculated value (PNU A143)–164

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!