11.07.2015 Views

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Setting parameters04/07 AWB8230-1541GBDebug mode (PNU C091)h Attention!The parameters and information listed in this section areintended only for specially <strong>tr</strong>ained personnel. Anychanges to the parameters listed here can causeunpredictable operating states.hDuring operation, PNU C091 must always contain thevalue 00.With PNU C091 = 01 the parameters listed in the table below aredisplayed.PNU Designation RUN b031= 10Display and value rangeManipulatedvariableRemarkC091 Debug mode j j 00: Disabled (do not show parameter) 0001: Enabled (display parameter)C092 Indication, DC linkvoltagej j 0000 - FFFF(do not change)– 1200C093C094C095Indication, debugmodeIndication, debugmode (bit)Selected debugmodej j 0000 - FFFF(do not change)j j Address range 0000 – FFFF h 0 – 7 bit selected(do not change)j j 00: Internal01: IO range– 1200– 1200– 00C121 O <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>pensation – – 0 - 65535 1. Default settingC122 OI <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>pensation – – 0 - 65535 1. Default settingC123 OI zero– – 0 - 65535 1./10. Default setting<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>pensationC190 Test safety mode – – 00: OFF– –01: ONC193 Test flag – – 0 - 65535 – –C194 Test flag mode – – 00: Standard– –01: Test routine mode02: Function routine modeC195 Initialization,coun<strong>tr</strong>y-coding– – 00: Japan01: Europe02: USAC196C197Assigned motorratingVoltage class,coding– – 200 V class• Japan, USA: 0.2; 0.4; 0.75; 1.5; 2.2; 3.7; 5.5; 7.5 [HP]• Europe: 0.2; 0.4; 0.55; 0.75; 1.1; 1.5; 2.2; 3.0; 4.0; 5.5; 7.5 [kW]400 V class• Japan: 0.2; 0.4; 0.75; 1.5; 2.2; 3.7; 5.5; 7.5 [HP]• USA: 0.2; 0.4; 0.75; 1.1; 1.5; 2.2; 3.7; 4.0; 5.5; 7.5 [HP]• Europe: 0.2; 0.4; 0.55; 0.75; 1.1; 1.5; 2.2; 3.0; 4.0; 5.5; 7.5 [kW]– – • 00: 200 V class• 01: 400 V class– Default settingd101 Indication – scaled output frequency 0.0 – 400.0 0.1 [Hz] –d102 Indication, DC link voltage 0.0 – 999.9 (DC+/DC–) 0.1 [V] –d104 Indication, thermal load on0.0 – 100.0 0.1 [%] –elec<strong>tr</strong>onicsd106 Indication, MCU number 0000 – 9999 1 –d107 Indication, IO MCU number 0000 – 9999 1 -d109 Indication, maximum DC link voltage 0.0 – 999.9 0.1 [V]Default setting142

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!