11.07.2015 Views

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Serial interface (Modbus)04/07 AWB8230-1541GBHoldingregisterFunctioncodeDesignationAccessrightsValue rangeManipulatedvariablehex1108 C006 Digital input 6 – functionDV51 onlyrw Values a PNU C001 –1109 C007 Reserved rw – –110 A C008 Reserved rw – –110B C011 Digital input 1 – logic rw 00: High signal <strong>tr</strong>iggers switching. –01: Low signal <strong>tr</strong>iggers switching.110C C012 Digital input 2 – logic rw Values a PNU C011 –110D C013 Digital input 3 – logic rw Values a PNU C011 –110E C014 Digital input 4 – logic rw Values a PNU C011 –110F C015 Digital input 5 – logic rw Values a PNU C011 –1110 C016 Digital input 6 – logicDV51 onlyrw Values a PNU C011 –1111 C017 Reserved rw – –1112 C018 Reserved rw – –1113 C019 Reserved rw – –1114 C021 Digital output 11 – signal rw 00: RUN: In operation –01: FA1: <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> reference value reached02: FA2: <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> signal – output frequencyexceeds value in PNU C042 (duringacceleration ramp) or PNU C043 (duringdeceleration ramp).03: OL: Overload warning – motor currentexceeds value in PNU C041.04: OD, PID con<strong>tr</strong>ol: Reference/actual valuedifference exceeds signalling threshold setwith PNU C044.05: AL: Fault – fault/alarm signal06: Dc: Warning – reference value at input O(0 to +10 V) lower than value in PNU b082or current signal at input OI below 4 mA.07: FBV: PID con<strong>tr</strong>ol – actual value monitoring(PV) signal on breach of limit valuesPNU C052/C053.08: NDc: Fault/warning dependent onPNU C077 – <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>munication watchdogtimer has expired: <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>munications arefaulty.09: LOG: Shows result of logic link performedthrough PNU C143.10: ODc: Fault/warning: Communicationoverload or interrupted (with optionalDE51-NET-CAN, DE51-NET-DP).1115 C022 Digital output 12 – signal rw Values a PNU C021 –1116 C023 Reserved rw – –1117 C024 Reserved rw – –1118 C025 Reserved rw – –172

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!