11.07.2015 Views

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

04/07 AWB8230-1541GB Reference and con<strong>tr</strong>ol signalinputsParameterizable digital inputsVarious functions can be assigned to terminals 1 to 5. Dependingon your requirements, you can configure these terminals asfollows:• start signal anticlockwise rotating field (REV),• selection inputs for various fixed frequencies (FF1 to FF4),• reset input (RST), etc.The terminal functions for programmable digital inputs 1 to 5 areconfigured with PNU C001 to C005, i.e. with PNU C001, youspecify the function of digital input 1, with PNU C002 the functionof digital input 2, etc. Note, however, that you cannot assign thesame function to two inputs at the same time.Programmable digital inputs 1 to 5 are configured by default asmake contacts. If, therefore, the function of an input terminal is tobe activated, the corresponding input must be closed (i.e. the inputterminal is, for example, connected to terminal P24). Deactivationresults in interruption of the input voltage (+24 V).h Attention!If an EEPROM error occurs, (fault message E08), allparameters must be checked to ensure that they arecorrect (especially the RST input).Table 21: Digital inputs 1 to 5PNU Terminal Adjustable inRUN modeValueC001 1 – a table 22 00C201C002 2 01C202C003 3 02C203C004 4 03C204C005 5 18C205For a detailed description of the input functions, see the pageslisted in table 22.DSTable 22: Function of the digital inputsValue Function Description aPage00 FWD Start/stop clockwise 7801 REV Start/stop anticlockwise 7802 FF1 Fixed frequency selection, bit 0 93(LSB)03 FF2 Fixed frequency selection, bit 104 FF3 Fixed frequency selection, bit 205 FF4 Fixed frequency selection, bit 3(MSB)06 JOG Jog mode 9607 DCB DC braking 12108 SET Selection of second parameter set 10009 2CH Second acceleration and 89deceleration time11 FRS Con<strong>tr</strong>oller inhibit and coasting to 80halt12 EXT External fault 11913 USP Unattended start protection 12015 SFT Parameter protection 13916 AT Select analog input 8218 RST Fault signal reset 18319 PTC PTC thermistor input (digital 117input 5 only)20 STA Start signal (3-wire) 9721 STP Stop signal (3-wire) 9722 F/R Direction of rotation (3-wire) 9723 PID Activation of PID con<strong>tr</strong>ol 13124 PIDC Reset integral <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponent 13127 UP Acceleration (motor94potentiometer)28 DWN Deceleration (motor94potentiometer)29 DWN-0Hz Reset frequency (motor94potentiometer)31 OPE Keypad 9850 ADD Add frequency offset 12451 F-TM Con<strong>tr</strong>ol signal terminals mode 98enabled52 RDY <s<strong>tr</strong>ong>Inverter</s<strong>tr</strong>ong>, reduce response time to 138con<strong>tr</strong>ol signals.53 SP-SET Second parameter set with 100special functions255 – Not used –79

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!