11.07.2015 Views

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

04/07 AWB8230-1541GB PID con<strong>tr</strong>olPNU Function RUN b031 =10Value Function DSA001Auswahl der Quelle fürden Sollwert– – 00 The setting range is limited by PNU b082 (raisedstarting frequency) and A004 (end frequency).• Potentiometer (optionale BedieneinheitDEX-KEY-6)• <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> [Hz]• Process variable [%] with active PID con<strong>tr</strong>ol(PNU A071 = 1)01 Analog-Eingang: Steuerklemmen O und OI02 Set value (PNU F001) of the keypad (arrow keysÍ/Ú). To save the set value, press the ENTER key(PNU A020).03 Serielle Schnittstelle (Modbus)10 Calculator: Calculated value (CAL) (a section“Rechenfunktionen”, page 1).A071 PID-Regler – j Activating PID con<strong>tr</strong>ol 0000 OFF, inaktiv01 ON, aktivA072 PID-Regler, P-Anteil j j 0.2 – 5.0 Proportional gain (K P )• Low values attenuate the con<strong>tr</strong>ol action.• High values can cause oscillation.A073 PID-Regler, I-Anteil j j 0.0 – 150 s Integral time constant 0.1A074 PID-Regler, D-Anteil j j 0.00 – 100 s Differential time constant 0.01A075 PID-Regler, Anzeigefaktor – j 0.01 – 99.99 Actual value indication, multiplication factor fordisplaying process variables.A076A077A078d004F001PID-Regler, EingangIstwertsignal PVPID-Regler,EingangssignaleinvertierenPID-Regler,AusgangssignalBegrenzungAnzeige PID-RückkopplungSollwert, Vorgabe überoptionale BedieneinheitDEX-KEY-…– j Selection of actual value input 0000 Analog-Eingang OI (4 … 20 mA)01 Analog-Eingang O (0 … 10 V)02 Serielle Schnittstelle (Modbus)10 berechneter Wert (PNU A143)(a section “Rechenfunktionen”, page 1)– j 00 OFF, inaktiv, Sollwert (+), Istwert (–) 0001 ON, aktiv, Sollwert (–), Istwert (+)– j 0.0…100 % Percentage limitation of PID con<strong>tr</strong>ol output 0.0j j – Indication only with active PID con<strong>tr</strong>ol(PNU A071 = 01).The display factor is set with PNU A075.0.00 – 99.99 (0.01 %)100.0 – 999.9 (0.1 %)1000 – 9999 (1 %)j j – • Frequenz: 0.0 – 400 Hz (0.1 Hz)• Prozessgröße 0.00 bis 9999 % bei aktiviertemPID-Regler (A071 = 01) mit Anzeigefaktor(A075).010.11.00–0.0129

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!