04/07 AWB8230-1541GB Automatic restart after a faultPNU Designation Adjustable in RUN mode Value Function DSNormalExtendedb001 Restart mode – j 00 The above fault messages are displayed when the associatedfault occurs (restart is not activated).b002b003Permissiblepower failuredurationWaiting time torestart01 A restart at the starting frequency after the time set underPNU b003 has elapsed.02 After the time set under PNU b003 has elapsed, the invertersynchronizes to the current motor rotation speed and themotor accelerates for the set acceleration time.03 After the time set under PNU b003 has elapsed, the invertersynchronizes to the current motor rotation speed and themotor brakes for the set deceleration time. A fault messageis then displayed.– j 0.3 to 1.0 s Here, you set a time duration during which the undervoltagecondition is met without the corresponding fault message inPNU E09 being initiated.– j 0.3 to 100 s Here, set a time which is to expire before an automaticrestart is initiated after a fault signal. This time can also beused in conjunction with the FRS function. During the delay,the following message appears on the LED display:001.01.0b004b005b006b007Instantaneous<strong>tr</strong>ipping of faultsignalNumber ofrestartattempts– j 00 In the event of an intermittent mains failure or undervoltage,the frequency inverter does not go into a fault state.01 In the event of an intermittent mains failure or undervoltage,the frequency inverter goes into a fault state.02 In the event of an intermittent mains failure or undervoltageat standstill and deceleration, the frequency inverterdoes not go into a fault state.– j 00 Sixteen restart attempts after intermittent mains failure orundervoltage.01 The number of restart attempts is not limited.Mains phase – j 00 Disabled 00failuredetection 1) 01 ActiveSynchronization frequency– j 0 to 400 Hz If the frequency corresponding with the motor’s speed ishigher than the frequency programmed here, the frequencyinverter synchronizes to the motor speed and accelerates tothe reference value.If the frequency corresponding with the motor’s speed islower than the frequency programmed here, the frequencyinverter starts at 0 Hz.1) The phase failure detection doe not work when you operate the frequency inverter DF51 with RFI filter.00000.00185

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!