04/07 AWB8230-1541GB7 Error messagesFault signalsThe DF51 frequency inverter features several built-in monitoringfunctions. To protect against damage, the inverter is automaticallyinhibited when a fault signal is detected. The connected motorthen coasts to a halt and the fault signal is indicated by the redALARM LED. The display shows an error code (E…). The DF51remains inhibited until the fault message is acknowledged. Toacknowledge the fault message:Display Cause Description• press the Stop key,• activate the digital input configured as RST,• switch off the power supply.E 01E 02E 03E 04<s<strong>tr</strong>ong>Inverter</s<strong>tr</strong>ong> overcurrent in staticoperation<s<strong>tr</strong>ong>Inverter</s<strong>tr</strong>ong> overcurrent duringdeceleration<s<strong>tr</strong>ong>Inverter</s<strong>tr</strong>ong> overcurrent duringacceleration<s<strong>tr</strong>ong>Inverter</s<strong>tr</strong>ong> overcurrent at standstillIn the following cases, the output current is too high:• The frequency inverter’s output is short-circuited.• The motor is blocked.• An excessive load is suddenly applied to the output.E 05 Overload The internal elec<strong>tr</strong>onic motor protection has switched off the output voltage because of anoverload.E 07 Overvoltage Overvoltage in regenerative mode.E 08 EEPROM fault The program memory is not operating reliably due to radio frequency interference, a con<strong>tr</strong>olvoltage short-circuit (P24–L) or excessive temperature.If the supply voltage is switched off while the RST input is active, an EEPROM fault mayoccur when the supply voltage is switched on again.E 09 Undervoltage Insufficient DC voltage (error-free elec<strong>tr</strong>onics function not possible; potential problems suchas overheating of motor and insufficient torque).E 11 Processor malfunction Processor is not working correctly, for example because of RFI or excessive temperature.E 12 External fault message An external fault signal is applied to a digital input configured as EXT input.E 13Unattended start protection<strong>tr</strong>ippedThe mains voltage was switched on or an intermittent interruption in the supply voltage hasoccurred while unattended start protection (input USP) was active.E 14 Ground fault Earth faults between the U, V or W terminals and earth are being reliably detected. Aprotective circuit prevents des<strong>tr</strong>uction of the frequency inverter at startup, but does notprotect the operating personnel.E 15 Mains overvoltage The mains voltage exceeds the permissible value. Shutdown about 100 s after activation ofpower supply.E 21 Overtemperature The built-in temperature sensor in the power section is measuring an operating temperatureabove the permissible limit value.E 22 Processor malfunction Processor is not working correctly, for example because of RFI or excessive temperature.E 30 Gate array fault Internal <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>munication error between CPU and the logical vector groups (gate array). TheIGBT power module is switched off immediately.E 35 Thermistor fault signal The resistance of the externally fitted PTC thermistor connected to the PTC input (digitalinput configured as PTC input) is too high.E60 Communication fault Communication with the frequency inverter timed out a PNU C076 and C077.Undervoltage (intermittentdisplay)The undervoltage signal appears briefly if the supply voltage (mains voltage or internal DClink voltage) is too low. The output to the motor (U, V, W) is switched off immediately.181

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!