11.07.2015 Views

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

04/07 AWB8230-1541GB2 EngineeringThis section describes the “Performance features/Technical data”and the requirements and standards relating to the followingissues:• Connection to power supply• EMC Directives for PDS drive systemsPerformance features/Technical dataGeneralStandards EN 50178, IEC 61800-3, EN 61800-3Ambient temperature 1)Mechanical shock resistanceOperating temperature °C –10 to +40 with rated current I e without reduced performance, up to +50 with clockfrequency reduced to 2 kHz and output current reduced to 80 % I eStorage, <strong>tr</strong>ansportation °C –25 to +70Vibration and impact, max. 5.9 m/s 2 (0.6 g) at 10 to 55 HzPollution degree VDE 0110 Part 2, pollution degree 2Climatic proofingClass 3K3 according to EN 50178 (non-condensing, average relative humidity 20 to90 %)Installation altitude m 0 to 1000 a.s.l., up to 4000 m with reduced output current of 2 % I e per 100 mMounting positionFree surrounding areasEmitted interferenceNoise immunityInsulation resistanceMains voltage balance F G 3%Vertically suspendedTotal harmonic distortion (THD) F G 10 %100 mm above and below deviceIEC/EN 61800-3 (with optional DE51-LZ… radio interference filter and screenedmotor cables)IEC/EN 61800-3, indus<strong>tr</strong>ial environmentOvervoltage category III according to IEC/EN 60204 up to 460 V + 10 % andcategory II up to 480 V + 10 %Leakage current to PE mA < 3.5 (to EN 50178), without EMC filterDegree of protectionProtection against direct contact Finger and back-of-hand proof (VGB 4)Protective isolation against switching circui<strong>tr</strong>y Safe isolation from the mains. Double basic isolation (to EN 50178).Protective measuresPower sectionDF51-320-…IP20Rated operational voltage V AC 230Rated voltage U e V 3 AC 180 to 264 V g 0%DF51-322-…Rated operational voltage V AC 230Rated voltage U e V 1/3 AC 180 to 264 V g 0%DF51-340-…Rated operational voltage V AC 400Rated voltage U e V 3 AC 342 to 528 V g 0%Mains frequency Hz 50/60 (47 to 63 g 0%)Overcurrent, earth fault, overvoltage, undervoltage, overload, overtemperature,elec<strong>tr</strong>onic motor protection: J monitoring and PTC input (thermistor or thermostat)15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!