Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Parameter list04/07 AWB8230-1541GBParameter list for user-definable settingsParameter list for DF51 frequency inverters.For a detailed description of the parameters, see the specifiedpage in the manual (AWB8230-1540GB).<s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> inverters DF51-322-… (single- and three-phase mainsconnection, rated voltage 230 V, 50/60 Hz) and DF51-340-…(three-phase mains connection, rated voltage 400 V, 50/60 Hz)work with the European operating system. The default settings arelisted in the DS column. The DF51-320-… devices can be usedonly on three-phase AC mains (200/215/220/230/240 V,50/60 Hz) and are supplied with the US version of the operatingsystem. The default values that apply here are shown in curlybrackets {xx}.PNU = parameter number displayed on the LCD keypad.RUN = access rights to parameters in RUN mode (RUN LED is lit).b031 = 10 = extended access rights to parameters in RUN mode(RUN LED is lit).• j = enabled• – = disabledEnter your application-specific settings in the “User setting”column in the table below.hThe parameters of the second parameter set (PNU 2…)always have the figure “2” in the first place and a greybackground in the table . On keypad DEX-KEY-…they are displayed only when this function is enabled(a PNU C001 = 08: SET).PNU Name RUN b031= 10Designation Value range DS Page UsersettingA001A201A002A202SetpointSourceSetpointSource [2]Start<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mandsStartCommands [2]– – Reference value sourceselection– – <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> reference valuesource selection(second parameter set)– – Start signal sourceselection– – Start signal sourceselection(second parameter set)00: Potentiometer (keypad) 01 8101: Analog input: con<strong>tr</strong>ol signal terminals Oand OI02: Functions PNU F001 or A02003: Serial interface (Modbus)10: Calculator (calculated value of CAL)Values a PNU A001 01 8101: Digital input (FWD/REV) 01 7202: Start key (keypad)03: Serial interface (Modbus)Values a PNU A002 01 72A003 f-Vmax – – Base frequency 30 to 400 Hz, up to value of PNU A004 [Hz] 50{60}A203 f-Vmax [2] – – Base frequency(second parameter set)30 to 400 Hz, up to value of PNU A004 [Hz] 50{60}A004 f-max – – End frequency (f max ) 30…400 Hz 50{60}A204 f-max [2] – – End frequency (f max )(second parameter set)A005 AT-Mode – – Analog input – selection(AT)Values a PNU A004 50{60}On active AT signal (a PNU C001 = 16) achangeover takes place between:00: Analog inputs O and/or OI01: Analog inputs O and OI (digital input ATis ignored)02: Analog input O or potentiometer(keypad)03: Analog input OI or potentiometer(keypad)6868686800 87230

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!