04/07 AWB8230-1541GB Operating softwareDrivesSoft2All settings for the data <strong>tr</strong>ansfer between PC and frequencyinverter must be confirmed. In the example below, the Onlineoperating mode has been selected.Figure 202:Parameters Upload and DownloadX Select the parameter set here:Upload: The parameters from the frequency inverter are uploadedto the PC.Download: The parameters are written from the PC to thefrequency inverter.hFor the Upload and Download <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mands, the frequencyinverter must be in STOP mode.Default settings/user-defined settingsWhen you receive your frequency inverter, the parameters containthe default setting. On the PC interface, these parameter valuesare shown in the Benutzer-Einstellung column. The values that canbe changed by the user have a green background; values changedby the user are indicated by a red corner.The changes take effect only when they have been made in Onlinemode or after an upload.Figure 203:User settings and device con<strong>tr</strong>olExample: With reference input “A001 = 2-REM: Optional operatorpanel” and con<strong>tr</strong>ol signal “A002 = 2-KeyOrPC” you activate the„Gerätesteuerung“ field. With the FWD, REV and Stopp & Resetbuttons, you can now start and stop the frequency inverter in bothdirections as well as specifying the reference frequency.hWhen signal “A001 = 2-REM…” is issued, the LED overthe START button lights up on the keypad of the <s<strong>tr</strong>ong>DF51.</s<strong>tr</strong>ong>When the FWD or REV signal is issued, the RUN LED lightsup.With the changes made here you can con<strong>tr</strong>ol the connectedfrequency inverter directly through the device con<strong>tr</strong>ol function onthe PC.hTo reset the parameters to their default values, selectKopieren: Standard-Einstellungen -> Benutzer-Einstellungen in the Bedienen menu. To also activate thedefault settings in the frequency inverter, select„Download“ after resetting the parameters. Thefrequency inverter is then in its factory default state again.215

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!