04/07 AWB8230-1541GB Displayed value (selection withPNU b089)PNU Run b031= 10Meaning Value range DS Page Required settingsC076 – j Communication –behaviour of frequencyinverter on<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>munication errorsC077 – j Communication – setmonitoring time(watchdog).C078 – j Communication –waiting time (latencybetween request andresponse)00: Switch off on fault signal E60 02 147 Individual01: Decelerate to standstill atdeceleration ramp and thenswitch off with error E60.02: No fault signal03: FRS: Free run stop (free coasting,= con<strong>tr</strong>oller inhibit)04 DEC: Braking to 0 Hz at setdeceleration ramp0…99.99 s 0.00 147 Individual0…1000 ms 0 147 IndividualDisplayed value (selection with PNU b089)When you operate the DF51 frequency inverter through the serialinterface with a fieldbus module (Modbus, CANopen,PROFIBUS DP) or an external keypad (DEX-KEY-…), the built-inkeypad is disabled. Only the Stop key remains enabled, but canalso be disabled with parameter b087. With PNU b089 you canselect a parameter to be displayed (d001 to d007) on the built-inkeypad’s display.Table 38: Selecting a display value in operation through the serial interface (PNU b089)Value Function Description Value range01 d001 Output frequency 0.0…400.0 Hz (0.1 Hz)02 d002 Output current 0.0…999.9 A (0.1 A)03 d003 Direction of rotation • F: Clockwise (forward) rotatingfield• o: STOP• r: Anticlockwise (reverse)rotating field04 d004 PID feedback 0.00…99.99 (0.01 %)100.0…999.9 (0.1 %)1000…9999 (1 %)05 d005 Status of digital inputs 1 to 5 –06 d006 State of digital outputs 11, 12 and relay K1 –07 d007 Scaled output frequency 0.00…9999 (0.01/0.1/1/10 Hz)When operating through the serial interface, observe thefollowing:• DF51 shows the value of d00x as selected with PNU b089 if:– DIP switch OPE/485 is set to 485;– the frequency inverter is connected through the serialinterface when the supply voltage is connected (POWER).• During operation through the serial interface, the received faultsignals (E xx, ) are displayed regardless of the setting inPNU b089. You can acknowledge the fault signal with the Stopkey or the Reset function (RST, a section “Resetting faultsignals (RST)”, page 183).• You can disable the Stop key with PNU b087.147

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!