Parameter list04/07 AWB8230-1541GBPNU Name RUN b031= 10Designation Value range DS Page Usersettingb001PowOff-RestartModeb002 t-PowOff-maxb003 t-RestartWaitb004 UV-Modeb005UV-RestartsMax– j POWER, restarting mode afterpower supply interruption– j POWER, permissible powersupply downtime– j POWER, waiting time beforeautomatic restart after powersupply failure– j POWER, fault signal onintermittent supply voltagefailure or undervoltage– j POWER, number of automaticrestarting attempts afterintermittent supply voltagefailure or undervoltageb012 I-OL – j Thermal overload, <strong>tr</strong>ippingcurrentb212 I-OL [2] – j Thermal overload, <strong>tr</strong>ippingcurrent (second parameter set)b013b213b021b221b022OL-ModeOL-Mode [2]ImaxMotorImaxMotor [2]ImaxMotorLimit– j Thermal overload,characteristic (torque curve)– j Thermal overload,characteristic (torque curve)(second parameter set)– j Motor current limitation –function– j Motor current limitation –function(second parameter set)– j Motor current limitation,<strong>tr</strong>ipping current00: Fault signal E 09, automatic restart at 00 1180Hz01: Automatic restart at set startingfrequency after expiry of time set withPNU b003.02: After the time set with PNU b003 haselapsed, the frequency invertersynchronizes to the current motorrotation speed and the motor isaccelerated to the reference current inthe set ramp times.03: After the time set under PNU b003 haselapsed, the inverter synchronizes tothe current motor rotation speed andthe motor brakes to a stop in the setdeceleration time. A fault message isthen displayed.0.3…25 s 1.0 1180.3…100 s 1.0 8000: Off: Disabled 00 11901: On: Enabled00: 16 restarts 00 11901: No limit0.2…1.2 x I e [A]Depending on frequency inverter’s ratedcurrent (I e )xx 1160.2…1.2 x I e [A]xx (I e ) 116Default, dependent on frequency inverters'srated current (Ie)00: Reduced torque 1 01 11601: Constant torque02: Reduced torque 2Values a PNU b013 01 11600: Off: Disabled 01 11401: On: Enabled in acceleration phase andat constant speed02: Enabled only at constant speedValues a PNU b021 01 1140.2…1.5 x I e [A]Default, dependent on frequency inverters'srated current (Ie)I e x 1.5 114236

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!