11.07.2015 Views

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

Frequency Inverter DF51... - Moeller.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

04/07 AWB8230-1541GB Holding register (wordvariable)HoldingregisterFunctioncodeDesignationAccessrightsValue rangeManipulatedvariablehex10D0 b081 Reserved rw – –10D1 b082 Increased starting frequency(e.g. at high static friction)rw 0.5…9.9 Hz 0.1 [%]10D2 b083 Carrier frequency rw 2…14 kHz 0.1 [%]10D3 b084 Initializing – function rw 00: Clear fault register –10D4 b085 Initialization, coun<strong>tr</strong>yspecificdefault settings10D5 b086 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> indication scalingfactor for value in PNU d00701: Load default settings (DS)02: Clear fault register and load default settings(DS)rw 00: Japan –01: Europe02: USArw 0.1…99.9 0.110D6 b087 STOP key (keypad) rw 00: Enabled –10D7 b088 Motor restart after removalof the FRS signal10D8 b089 Display value with a fieldbusmodule (RS 485)DF51 only10D9 b090 Braking <strong>tr</strong>ansistor,permissible percentage dutyfactor within a 100 sintervalDV51 only10DA b091 Behaviour after a STOPsignal10DB b092 Device fan, configurationDV51 only10DC b095 Braking <strong>tr</strong>ansistor, con<strong>tr</strong>olDV51 only10DD b096 Braking <strong>tr</strong>ansistor, startingvoltage thresholdDV51 only01: Disabledrw 00: Restart with 0 Hz –01: Restart with the determined outputfrequency (current motor speed)r 01: Output frequency (d001) –02: Output current (d002)03: Direction of rotation (d003)04: Actual value (PV) (d004)05: State of digital inputs (d005)06: State of digital outputs (d006)07: Scaled output frequency (d007)rw 0…100 % –0 %: Braking <strong>tr</strong>ansistor disabled> 0 %: Braking <strong>tr</strong>ansistor enabledrw 00: DEC, braking to 0 Hz with deceleration ramp –01: FRS, free run stoprw 00: The built-in fan is always switched on. –01: The built-in fan is switched on duringoperation (RUN mode); automatic switchoff5 min after Stop signal.02: Built-in fan operation is temperaturecon<strong>tr</strong>olled.rw 00: Function disabled –01: Enabled in RUN mode02: Always enabledrw 330…395 V (Ue = 230 V) 1 [V]660…790 V (Ue = 400 V)Default, dependent on rated voltage of DV51 (Ue)169

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!