12.07.2015 Views

Temperature Controller - Staveb AG

Temperature Controller - Staveb AG

Temperature Controller - Staveb AG

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Appendix ASpecificationsFor the setting ranges for each sensor input, see p. A-3.Table A.ATechnical/ControlSupply voltage 100…240V AC, 50/60 Hz 24V AC, 50/60 Hz or 24V DCOperating voltage range85…110% of rated supply voltagePower consumption 4.3 VA @ 120V AC, 7 VA @ 240V AC 4 VA/2.5 WRecommended line fuseType: T2A, 250V AC, time lag, low shut-off capacity ➊Sensor input ThermocoupleK, J, T, E, L, U, N, R, S, B➋Platinum resistance thermometerPt100, JPt100 (1 mA controller source current)Non-contact temperature sensorK10…70°C, K60…120°C, K115…165°C, K160…260°C(simulates Type K thermocouple)Voltage input0…50 mVControloutputAlarm outputON/OFF Relay outputON/OFF Voltage output (PNP type)SPST-NO, 250V AC @ 2 A or 30V DC @ 2 A (resistive load),electrical life: 100,000 operations, min. applicable load 1V, 1 mAOutput voltage 12V DC, max. load current 21 mA, with current limit circuitSPST-NO, 250V AC @ 1 A or 30V DC @ 2 A (resistive load),electrical life: 100,000 operations, min. applicable load 1V, 1 mA2-PID (auto-tune and self-tune) or ON/OFF controlDigital setting using front panel keys or 900Builder software7-segment digital displays and LED indicatorControl methodSetting methodIndication methodIndication Thermocouple(±0.5% of indication value or ±1°C, whichever is greater) ± 1 digit max. ➌accuracyPlatinum resistance thermometer (±0.5% of indication value or ±1°C, whichever is greater) ±1 digit max.Analog input±5%FS±1 digit max.Hysteresis0.1…999.9 EU (in units of 0.1 EU)Proportional band (P)0.1…999.9 EU (in units of 0.1 EU)Integral time (I)0…3999 (in units of 1 second)Derivative time (D)0…3999 (in units of 1 second)Control period1…99 (in units of 1 second)Manual reset value 0.0…100.0% (in units of 0.1%)Alarm setting range–1999…+9999 (decimal point position dependent on input type)Sampling period500 ms➊➋➌Available from Little Fuse or Bussmann (part no. GDC-2A).For the setting ranges for each input, see p. A-3.The indication of K thermocouples in the –200…+1300°C range, T and N thermocouples at a temperature of–100°C or less, and U and L thermocouples at any temperature is ±2°C±1 digit maximum. The indication of Bthermocouples at a temperature of 400°C or less is unrestricted. The indication of R and S thermocouples at atemperature of 200°C or less is ±3°C±1 digit maximum.A-1 Publication 900-UM003C-EN-E - January 2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!