Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Setting Parameters01/02 AWB8230-1413GBPNU Function Adjustable in RUN mode Value Function WENormalExtendedA001A011A012A013A014d004F001A072A073A074A075A076<s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong>setpointdefinition<s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> withminimumsetpoint value<s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> withmaximumsetpoint valueMinimumsetpoint valueMaximumsetpoint valueActual value xfactorInput/displayfrequencyvalueP <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponentof the PIDcon<strong>tr</strong>olI <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponent ofthe PID con<strong>tr</strong>olD <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponentof the PIDcon<strong>tr</strong>olSetpoint factorof the PIDcon<strong>tr</strong>olInput actualvalue signal forPID con<strong>tr</strong>ol– – 00 Definition with the potentiometer on the keypad 0101 Definition through analog input O (0 to 10 V) or OI(4 to 20 mA)02 Definition through PNU F001 <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong>/or PNU A020– j 0 to 400 Hz Here, the frequency that corresponds to the minimumvoltage setpoint value under PNU A013 is set.– j 0 to 400 Hz Here, you can set the frequency that corresponds to themaximum voltage setpoint value under PNU A014.– j 0 to 100 % The minimum setpoint value entered here relates to themaximum possible voltage or current setpoint (10 V or20 mA).– j 0 to 100 % The maximum setpoint value entered here relates to themaximum possible voltage or current setpoint (10 V or20 mA).j j – Only with active PID con<strong>tr</strong>ol. The factor is set underPNU A075, from 0.01 to 99.99; default setting: 1.0.j j 0.1 to 400 Hz Resolution g0.1 HzThe setpoint can be defined using various methods:• With PNU F001 or A020: Enter the value 02 underPNU A001.• Using the potentiometer on the keypad: Enter the value00 under PNU A001.• With a 0 to 10 V voltage signal or a 4 to 20 mA currentsignal at input terminals O or OI: Enter the value 01 underPNU A001.• With the digital inputs configured as FF1 to FF4. Afterselection of the required fixed frequency stage using FF1to FF4, the frequency for the respective stage can beentered.The display of the setpoint value is independent of whichmethod was used to set the setpoint value.j j 0.2 to 5.0 Adjustment range of the proportional <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponent of thePID con<strong>tr</strong>olj j 0 to 3600 s Adjustment time T i of the integral <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponent of thePID con<strong>tr</strong>olj j 0.0 to 100 s Adjustment time T d of the differential <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponent of thePID con<strong>tr</strong>ol– – 0.01 to 99.99 The display of the frequency setpoint or actual value can bemultiplied by a factor, so that process related quantities(e.g. flow or similar) can be displayed instead of thefrequency.– – 00 Actual value signal present on analog input OI (4 to 20 mA) 0001 Actual value signal present on analog input O (0 to 10 V)0.00.00100–0.01.01.00.01.00120

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!