01/02 AWB8230-1413GB PID con<strong>tr</strong>olScaling adjustmentScaling adjustment <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> scaling allow the setpoint <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> actual valueto be displayed <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> the setpoint value to be entered directly in thecorrect physical unit. For this purpose, 100 % of the returnedactual value is taken as a basis. By default, inputs <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> displays arebased on 0 to 100 %.Example: In the first diagram in figure 123, 20 mA of the feedbacksignal correspond to 100 % of the PID internal factor. If forexample the flow rate is currently 60 m 3 /min with a feedbacksignal of 20 mA, the parameter is set to 0.6 (= 60/100) withPNU A075. With PNU d004, the process corrected value can bedisplayed <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> the setpoint value can be entered directly as aprocess corrected quantity.G1G1w [%]PNU F001= 0 – 100 %x4 – 20 mAPNU d001= 0 – 100 %B1w [%]PNU F0010 – 60m 3 /minx4 – 20 mAPNU d0010 – 60m 3 /minB1M3~Factory default setting PNU A075 = 0.6aP1M3~aP1Figure 124: Example for scaling adjustmentw: Setpointx: Returned actual valuea FanSummary of the relevant parametersThe <s<strong>tr</strong>ong>DF6</s<strong>tr</strong>ong> frequency inverters use the same parameters for bothfrequency con<strong>tr</strong>ol <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> PID modes. The designations of therespective parameter relate only to frequency con<strong>tr</strong>ol mode, as thismode is used in most cases. When PID mode is used, some of theparameters have other designations.The table below contains an explanation of these parameters forboth frequency con<strong>tr</strong>ol mode <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> PID mode:PNUMeaning of the parameters when used infrequency con<strong>tr</strong>ol modePID moded004 – Indication of the returned actual valueF001 Indication of the output frequency Indication of the setpoint valueA001 Definition of frequency setpoint value Setpoint definitionA011 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> at minimum setpoint value (units: Hz) Feedback percentage actual value for lower acceptancethreshold (units: %)A012 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> at maximum setpoint value (units: Hz) Feedback percentage actual value for upper acceptancethreshold (units: %)A013 Minimum setpoint value (units: Hz) Lower acceptance threshold for voltage or current on theactual value input (units: %)A014 Maximum setpoint value (units: Hz) Upper acceptance threshold for voltage or current at theactual value input (units: %)A021 to A035 Fixed frequencies 1 to 15 Digital adjustable setpoint values 1 to 15123

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!