Installation01/02 AWB8230-1413GBNo. Function Level WE Technical data, descriptionRelay outputsK11K12K14K23K24K33K34Programmable relayoutput, changeovercontactProgrammable relayoutput, make contactProgrammable relayoutput, make contactAL = fault messageK11 K14K12Default settings:• Run signal: K11K14 closed.• Fault signal or power supply switched off:K11-K12 closedCharacteristics of the relay contacts:•K11K14– Maximum 250 V AC/2 A (resistive) or0.2 A (inductive, p.f. = 0.4);minimum 100 V AC/10 mA– Maximum 30 V DC/8 A (resistive) or0.6 A (inductive, p.f. = 0.4);minimum 5 V DC/100 mA•K11K12– Maximum 250 V AC/1 A (resistive) or0.2 A (inductive, p.f. = 0.4);minimum 100 V AC/10 mA– Maximum 30 V DC/1 A (resistive) or0.6 A (inductive, p.f. = 0.4);minimum 5 V DC/100 mA––FA1 = frequency reachedK23 K24RUN = Run signalCharacteristics of the contacts:• Maximum 250 V AC/5 A (resistive) or1 A (inductive, p.f. = 0.4);• Maximum 30 V DC/5 A (resistive) or1 A (inductive, p.f. = 0.4);• minimum 5 V DC/100 mAAnalog outputsK33 K34AM Voltage output 0 to +10 V H <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> actual value Resolution: 8-bitLoad carrying capacity: 2 mAReference potential: Terminal LAMI Current output 4 to 20 mA Resolution: 8-bitR B F 250 OReference potential: Terminal LFM <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> output 0 to +10 V H <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> actual value(0 to 50 Hz)Configurable, monitored DC voltage; 10 Vcorresponds to set end frequency (50 Hz).Accuracy: g5 % from final valueLoad carrying capacity: 1.2 mAReference potential: Terminal CM1Con<strong>tr</strong>ol signal terminal wiringWire the con<strong>tr</strong>ol signal terminals as appropriate for theirapplication. For ins<strong>tr</strong>uctions for changing the function of thecon<strong>tr</strong>ol signal terminals, see section “Programming the Con<strong>tr</strong>olSignal Terminals”, page 53.Use twisted or screened cables for connecting to the con<strong>tr</strong>ol signalterminals. Earth the screen on one side with a large contact areaconnection near the frequency inverter. The cable length shouldnot exceed 20 m. For longer cables, use a suitable signal amplifier.Caution!Never connect terminal P24 with terminals L, H, OI or FM.Caution!Never connect terminal H with terminal L.40

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!