01/02 AWB8230-1413GB St<s<strong>tr</strong>ong>and</s<strong>tr</strong>ong>ard form for user definedparameter settingsSt<s<strong>tr</strong>ong>and</s<strong>tr</strong>ong>ard form for user defined parameter settingsThe <s<strong>tr</strong>ong>DF6</s<strong>tr</strong>ong> frequency inverters have programmable parameters. Inthe free Setpoint columns below, you can list the changes youhave made from the default settings.PNU Function Units WE Page SetpointA001A002<s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> setpoint input through• 00: Potentiometer• 01: Analog inputs O, O2 or OI• 02: PNU F001 or A020• 03: RS 485 serial interface• 04: Optional module in slot 1• 05: Optional module in slot 2Start signal definition through• 01: Input FWD/REV• 02: ON key• 03: RS 485 serial interface• 04: Optional module in slot 1• 05: Optional module in slot 2– 01 107– 01 108A003 Base frequency [Hz] 50 108A203 Base frequency (second parameter set) [Hz] 50 108A004 Maximum end frequency [Hz] 50 108A204 End frequency (second parameter set) [Hz] 50 108A005 AT selection• 00: AT input switches between analog inputO<s<strong>tr</strong>ong>and</s<strong>tr</strong>ong>OI• 01: AT input switches between analog inputO<s<strong>tr</strong>ong>and</s<strong>tr</strong>ong>O2– 00 60A006O2 selection• 00: O2 signal only• 01: Sum of signals at O2 <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> O/OI withoutdirection reversal• 02: Sum of signals at O2/O or OI withdirection reversal– 00 60A011 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> at minimum setpoint value (terminal O-L) [Hz] 0.00 62A012 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> at maximum setpoint value (terminal O-L) [Hz] 0.00 62A013 Minimum setpoint value (terminal O-L) [%] 0 62A014 Maximum setpoint value (terminal O-L) [%] 100 62A015 Starting frequency (terminal O-L)• 00: Apply PNU A011 to motor• 01: Apply 0 Hz to motor– 01 62A016 Analog input filter time constant – 8 62A019 Fixed frequency selection• 00: Binary selection through digital inputs FF1 to FF4• 01: Bitwise selection through digital inputsSF1 to SF7– 00 69A020 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> setpoint definition (PNU A001 must be 02) [Hz] 0.00 69A220 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> setpoint definition (PNU A001 must be 02) [Hz] 0.00 69(second parameter set)A021 1. Fixed frequency [Hz] 0.00 69A022 2. Fixed frequency [Hz] 0.00 69A023 3. Fixed frequency [Hz] 0.00 69167

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!